Place of Origin: | America |
Brand Name: | TYCO |
Certification: | CE |
Model Number: | V23401-T1705-D501 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | CARTON |
Delivery Time: | In stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 10000PCS/WEEK |
Material: | Iron | Clour: | Gray |
---|---|---|---|
Diameter: | 50mm | Temperature: | -15-120 |
TYCO: | TYCO | V23401-T1705-D501: | V23401-T1705-D501 |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
Model | Standard1 | Standard2 | Standard3 |
Excitation Input | AC7Vrms 10kHz | ||
Primary Side | R1 - R2 | ||
Transformation Ratio | 0.286±10% | ||
Electrical Error | 60'Max. | ||
Input Impedance: Zro |
120Ω±20%
|
V23401-T1705-D501
V23401-D1009-B114
V23401-D1009-B122
V23401-D1009-B101
V23401-D1009-B102
V23401-S1001-B122
V23401-S1001-B101
V23401-S1001-B109
V23401-S1001-B110
V23401-T1002-B114
V23401-H1002-B114
V23401-T1002-B122
V23401-H1002-B101
V23401-T1002-B102
V23401-H1002-B102
V23401-T1005-B114
V23401-H1005-B114
V23401-T1005-B122
V23401-H1005-B122
V23401-T1005-B101
V23401-H1005-B101
V23401-T1005-B102
V23401-H1005-B102
V23401-T1009-B114
V23401-H1009-B114
V23401-T1009-B122
V23401-H1009-B122
V23401-T1009-B101
Diagnosis alarms are triggered in line with acyclic services according to DPV1. A diagnosis alarm is triggered upon the encoder having detected a probably incorrect position. The next position data telegram is added a high priority bit in the function code (bit 1) by the encoder what makes the control transmit a acyclic diagnosis alarm request. The encoder responds by an acyclic diagnosis telegram. “Data Unit” (DU) of this telegram provides the following structure: Octets 1 to 6 correspond to the diagnosis telegram of cyclic data exchange.
A diagnostic warning is triggered upon the encoder recognizing that specific internal tolerance limits have been achieved. Conversely to alarms a warning does not consequently mean a position error. The process sequence of a diagnostic warning is fully identical to that of a diagnosis alarm described in the above. The difference is made in „Type of Diagnosis“ defining several reasons for warning.
The parameterization master utilizes acyclic telegrams in line with PROFIBUS-DPV1 to read and if required to write addressed data in the DP slave by slot, index and parameter number. Prior condition is that the DP slave is in Data Exchange mode. Acyclic data communication utilizes system functions DS_Read and DS_Write. DS_Write is appropriate for writing parameters („Change Parameter“). A parameter reading operation by DS_Read („Request Parameter“) is always preceded by DS_Write supplying the slave with all necessary information on the requested parameter read access. Successful exit of DS_Write may take several bus cycles, afterwards DS_Read can be launched
Input impedance Tolerance: ± 15 % |
Tolerance: ± 15 % |
DS_Write SIEMENS controls apply system function SFB53 / WRREC for DS_Write. Parameters to be delivered are among others index and ID (Slot), “Index=47” as encoder profile parameter, Index=255“ for I&M parameters. The slot address is the “ID”. For Slot1 it is the programmed E/A address of telegram 81, in the examples below 512 = 0x200. Slot0 is addressed via the diagnosis address of the DP-Slaves, in the examples below 4093 = 0xFFD. An additional data block must be prepared for accommodating more parameters. The schematic structure of this data block is described in the following. Length depending on read/ write access and parameter length are between 10 and 16 bytes.