Place of Origin: | America |
Brand Name: | TYCO |
Certification: | CE |
Model Number: | V23401-T8002-B802 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | CARTON |
Delivery Time: | In stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 10000PCS/WEEK |
Material: | Iron | Clour: | Gray |
---|---|---|---|
Diameter: | 60mm | Temperature: | -20-120 |
TYCO: | TYCO | V23401-T8002-B802: | V23401-T8002-B802 |
high temperature Encoder Iron explosion-proof
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
Model | Standard1 | Standard2 | Standard3 |
Excitation Input | AC7Vrms 10kHz | ||
Primary Side | R1 - R2 | ||
Transformation Ratio | 0.286±10% | ||
Electrical Error | 60'Max. | ||
Input Impedance: Zro | 120Ω±20% |
V23401-T8002-B802
V23401-U2020-B209
V23401-U2020-B209
V23401-U2020-B210
V23401-T2014-B209
V23401-T201E-E209
V23401-T2G09-E202
V23401-H6009-B601
V23401-D1001-B114
V23401-T2002-B209
V23401-T2009-B202
V23401-U1016-B110
V23401-T2009-E202
V23401-U6119-B609
V23401-U6019-B609
V23401-S1201-C610
V23401-T2009-B202
V23401-T2099-C502
V23401-H1005-D101
V23401-U6019-B609
V23401-T2679-C302
V23401-U6119-B609
V23401-U6019-B609
V23401-U6319-B609
V23401-T2014-B209
V23401-T2014-B209
V23401-T201E-E209
V23401-T2G09-E202
V23401-H6009-B601
Slave configuration The master transmits a Check Configuration Request (Chk_Cfg). The master informs the slave about volume (number of data bytes) and structure (data consistency) of the input and output ranges to be exchanged. The slave compares this configuration with its own configuration. Diagnosis request prior to data exchange The master transmits another Slave Diagnose Request (Slave_Diag), the slave responds by a Slave Diagnose Response. The master now verifies if parameterization and configuration coincide with the data stored in the slave. If the data requested by master is admissible and correct the slave signalizes its readiness for user data transfer via the diagnostic data.
Data_Exchange The slave now will react exclusively to the master it was parameterized and configured by. The master transmits a user data request (Data_Exchange), the slave responds by a user data response informing the master about any current diagnostic events. The slave provides the true diagnosis and status information only after the master’s diagnosis telegram.
Input impedance Tolerance: ± 15 % |
Parameterization By parameterization the control provides the slave with information required for process data exchange. The information comprises PROFIBUS –specific data (octet 1 to 6) and user-specific information as for example the required measuring resolution. User-specific information can be altered any time during the projecting phase using an input window
The slave verifies the data transmitted by master with its own stored data upon admissibility. The slave will not inform the master of the result until a diagnosis request after configuration.
Configuration defines the scope of cyclic process data communication in both directions. The slave compares the target configuration with its own stored one and informs the master about the result in a subsequent diagnosis request. From the master’s point of view, encoder position values are input data and data transmitted to the encoder are output data.