Place of Origin: | America |
Brand Name: | TYCO |
Certification: | CE |
Model Number: | V23401-T2009-B201 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 10000pcs/week |
TYCO: | TYCO | V23401-T2009-B201V23401-T2009-B201: | V23401-T2009-B201 |
---|---|---|---|
COLOR: | BLACK | Material: | Iron |
Temperature: | 20-120 | Demention: | 100mm |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
V23401-T2009-B201
V23401-T2014-B201
V23401-H2014-B202
V23401-T2014-B202
V23401-T2015-B214
V23401-T2009-B202
V23401-T2002-B209
V23401-T2014-B209
V23401-T2014-E209
V23401-T2099-C502
V23401-H1005-D101
V23401-T1002-B122
V23401-H1002-B101
V23401-T1002-B102
V23401-H1002-B102
V23401-T1005-B114
V23401-H1005-B114
V23401-T1005-B122
V23401-H1005-B122
V23401-T1005-B101
V23401-H1005-B101
V23401-T1005-B102
V23401-H1005-B102
V23401-T1009-B114
V23401-H1009-B114
V23401-T1009-B122
V23401-H1009-B122
V23401-T1009-B101
V23401-H1009-B101
V23401-T1009-B102
You have configured the keyboard function "Emergency Acknowledgment" on the "Toolbar" tab of the Alarm Control. Procedure 1. Click the "Emergency acknowledgment" button . The "Emergency Acknowledgment for Messages" dialog opens. 2. Select a server. In the "Message Number" box, enter the number of the message to be acknowledged. Click the "Request" button. In the message window, the message now appears in the color that you specified for an acknowledged message.
In the dialog for the selection of the servers, only server projects are shown whose "Package" is loaded onto the computer.
During runtime, you can sort the messages in the message window on the basis of message blocks. You sort the message blocks either via the "Sort Dialog" keyboard function or directly via the column headers of the message blocks. Examples for sorting messages: ● Display of messages in descending order by date, time and message number The most recent message is displayed at the top. ● Display of messages according to priority. To apply this sorting method, you must have specified the priorities of messages in Alarm Logging and configured the "Priority" message block in the Alarm Control. As a result, in a single-line message view, only the top-priority message appears in the message window. A message with a lower priority is not displayed, even if it is more recent. Normally, the messages are shown in chronological order. ● Display of messages in ascending or descending order based on various message blocks, allowing for user-defined sorting during runtime. ● The "Status" message block is sorted according to the status type and not according to the configured status texts. If sorting is in ascending order, the messages are sorted in the following order: Came In, Went Out, Acknowledged, Locked, Unlocked, System Acknowledgement, Emergency Acknowledgement, Came In/Went Out. Note You can also specify the sort criteria during configuration in the Alarm Control by clicking the "Sorting..." button on the "Message Lists" tab. You configure the sort criteria for the hit list on the "Hit List" tab
You have configured the "Sort Dialog" keyboard function on the "Toolbar" tab of the Alarm Control. Procedure 1. Click the "Sort Dialog" button . 2. In the "Sort By" field, select the message block by which to sort first. Select the relevant check box to specify sorting in ascending or descending order. If you want to sort by more than one message block, select the other message blocks in the desired order in the "Then By" lists.
When sorting using the column header, you can specify the sort order for more than four message blocks. An arrow and a number are shown in the column header (right-justified). The arrow indicates the sort direction, i.e. ascending or descending. The number beside the arrow indicates the sort order of the message blocks. Requirement ● You have selected the "Sort by Column Header" check box on the "Parameters" tab of the Alarm Control. ● You have deactivated the "Autoscroll" keyboard function.
Click the column header of the message block you want to sort by first. The number "1" is displayed, and the arrow points upwards for ascending sort order. 2. If you want to sort in descending order, click the column header again. 3. If you want to clear the sorting of the message block, click the column header a third time. 4. If you want to sort on the basis of several message blocks, click the header columns of the respective message blocks in the desired sequence.
Sorting is not affected by events or changes in the message block configuration. If you have defined a message block as a sort criterion in the sort dialog and you subsequently delete this block from the message line, the specified sort order remains in place. In the sort dialog, a blank field is displayed instead of the deleted message block. If you have not specified another sort order and the deleted message block is included again in the message block configuration of the Control, the messages are again shown in the original sort orde
Function used to switch the message window to show the list of hidden messages.
This function is used to switch the message window to show the messages in the long-term archive list | |
If you do not want to use the toolbar to operate the message window, you can use the functions available in the "Standard Functions/Alarm" group of the "Global Script" editor. | |
This function is used to switch the message window to show the messages in the short-term archive list.
|
This function can be used to acknowledge a central signaling device assigned to the selected message.
This function selects the previous message and shifts the visible range in the message window, if necessary
Depending on the current display type (message list, short-term archive list, long-term archive list), this function is used to generate a printout of the currently pending or archived messages that meet the selection criteria. The print layout depends on the type of the message window
This function starts a printout of the current view of the Control. All messages meeting the selection criteria are printed.
This function can be used to change the Autoscroll behavior of the message window
This function can be used to change the Autoscroll behavior of the message window
This function locks the currently selected message in Alarm Control in the message list, short-term archive list and long-term archive list views. If the lock list view is selected, this function is used to unlock the currently selected message.
This function can be used to define a filter for selection of messages to be displayed in the message window. The filter criteria must be defined within the action script.]
In order to operate the WinCC Alarm Control by means a function, you must configure the corresponding function. This is done by making objects dynamic with standard functions of Global Script in the Graphics Designer. In principle, any object can be used to operate the Alarm Control. In order to achieve similarity with the toolbar of a message window, the following example will insert a graphic object for acknowledging a message. Requirement ● You have configured the example project for Alarm Control. ● You have opened the picture containing the configured Alarm Control in the Graphics Designer.