Place of Origin: | America |
Brand Name: | TYCO |
Certification: | CE |
Model Number: | V23401-H2009-B222 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 10000pcs/week |
TYCO: | TYCO | V23401-H2009-B222: | V23401-H2009-B222 |
---|---|---|---|
America: | America | COLOR: | BLACK |
Material: | Iron | Wire: | Wire |
Temperature: | 20-120 | Demention: | 100mm |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
V23401-H2009-B222
V23401-H2001-B222
V23401-T2001-B201
V23401-H2001-B201
V23401-T2001-B202
V23401-H2001-B202
V23401-T2009-B214
V23401-H2009-B214
V23401-T2009-B222
V23401-H2009-B222
V23401-T2009-B201
V23401-H2009-B201
V23401-T2009-B202
V23401-H2009-B202
V23401-T2010-B214
V23401-H2010-B214
V23401-T2010-B222
V23401-H2010-B222
V23401-T2010-B201
V23401-H2010-B201
V23401-T2010-B202
V23401-H2010-B202
V23401-T2014-B214
V23401-H2014-B214
V23401-T2014-B222
V23401-H2014-B222
V23401-T2014-B201
V23401-H2014-B202
V23401-T2014-B202
V23401-T2015-B214
V23401-T2009-B202
V23401-T2002-B209
V23401-T2014-B209
V23401-T2014-E209
V23401-T2099-C502
V23401-H1005-D101
V23401-T1002-B122
V23401-H1002-B101
V23401-T1002-B102
The update of the controls is based on the archiving cycle. | activate the option "Refresh cyclic values" in the "Tag Logging" editor. |
If you have configured a fast acquisition cycle but a slow archiving cycle, you may get the impression when displaying the values that no values are archived |
To do so, select the "Tag logging" folder in the navigation area |
If you want the values in the controls to be updated with the acquisition cycle, |
The cyclic-selective process value archiving is started in Runtime as soon as a start event occurs. The process values are subsequently acquired at fixed cycles and stored in the archive database. Cyclic process value archiving ends: ● When a stop event occurs ● When you terminate Runtime ● When the start event no longer exists
Start event and stop event are determined by the value of the configured tag or by the return value of a script. You configure the tags or scripts in Tag Logging in the properties of the process value tags in the "Archiving" area.
Each process tag in WinCC (B) corresponds to a certain process value in the memory of one of the connected automation systems (A). Process value archiving begins on the occurrence of the start event (1). The acquisition cycle (2) controls when the process value is read from the memory of the automation system. The Runtime component of the archive system (C) processes the process value: ● Whether the process value is archived at all depends on the way you have configured a hysteresis. The process value must be changed by a certain amount or percentage (3). ● The processing method (4) determines how the acquired process values are processed, for example, by averaging. Until the occurrence of the Stop event (6), the archiving cycle (5) determines when the processed process value is written to the archive database (D)