Place of Origin: | America |
Brand Name: | TYCO |
Certification: | CE |
Model Number: | V23401-H2010-B201 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 10000pcs/week |
TYCO: | TYCO | V23401-H2010-B201: | V23401-H2010-B201 |
---|---|---|---|
America: | America | Material: | Iron |
Color: | Black | Temperature: | 20-120 |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
V23401-H2010-B201
V23401-U2020-B209
V23401-D1001-B101
V23401-T2202-C309
V23401-T2014-B209
V23401-T2014-B209
V23401-T2G09-E202
V23401-H6009-B601
V23401-D1001-B114
V23401-T2002-B209
V23401-T2009-B202
V23401-T2014-B209
V23401-U1016-B110
V23401-T2014-E209
V23401-T2009-E202
V23401-U6119-B609
V23401-U6019-B609
V23401-S1201-C610
V23401-T2015-B201
V23401-H2009-B202
V23401-D1001-B114
V23401-D1001-B122
V23401-D1001-B101
V23401-D1001-B102
V23401-D1008-B114
V23401-D1008-B122
V23401-D1008-B101
V23401-D1008-B102
On the "Message Blocks" tab, select the "Time" system block and the two user text blocks "Message Text" and "Point of Error".
On the "Message Lists" tab, specify the message blocks and the order in which they are to be displayed in the message window. Using the arrow keys, move the selected message blocks from the list of "Existing Message Blocks" to the list of "Selected Message Blocks". Change the order by selecting a message block and clicking
Click "OK" to close the dialog, and save your settings in the Graphics Designer.
How to Configure Buttons for Changing Message Tags Configuration of the WinCC Alarm Control
You have configured four single messages in Alarm Logging. In order to reproduce the example for the Alarm Control, you configure four buttons in the Graphics Designer that you use during runtime to set and reset the binary message tags of the individual messages. The message window shows the message statuses with the configured colors.
In the object palette of the Graphics Designer, select the "Standard" tab and click the "Button" object in the "Windows Object" group. Position the cursor on the image at the spot where you want to insert the button, and enter the text "Tank1". 2. Select "Properties" in the shortcut menu. 3. Make the "Left-click" event dynamic by establishing a direct link between the constant "1" and the tag "Tank1".
Make the "Right-click" event dynamic by establishing a direct link between the constant "0" and the tag "Tank1". 5. Likewise, configure three additional buttons with "Tank2", "Tank3" and "Motor". 6. Save your settings in the Graphics Designer.
How to Configure the Alarm Control in the Graphics Designer (Page 1264) Configuration of the WinCC Alarm Control
The hit list displays statistics for the archived messages in the message window. In addition to statistics, a limited selection of configured message blocks can also be displayed in the hit list. In the case of variable contents, the message blocks display the data for the last incoming message. You assemble the columns of the hit list yourself, which consist of the message blocks and the statistics. The following statistical calculations are available fro messages: ● Frequency of a message number. The frequency is only increased, if a message with status "Came In" is included in the archive. If the frequency of a message number in the selected message range is "0", no entry is made in the statistics for this message number. ● The cumulative duration of a message number in seconds for status "Came In/Came In"(+/ +),"Came In/Went Out"(+/-), the status "Came In/Initial Acknowledgment"(+/*1) or the status "Came In/Second Acknowledgement"(+/*2). ● The average duration of a message number in seconds for status "Came In/Came In"(+/ +),"Came In/Went Out"(+/-), the status "Came In/Initial Acknowledgment"(+/*1) or the status "Came In/Second Acknowledgement"(+/*2). Only the "Acknowledgment", "System Acknowledgment" and "Emergency Acknowledgment" acknowledgment states are included in the statistics calculation of acknowledgment times. Note Messages with the states "Acknowledgment", "System acknowledgment", "Emergency acknowledgment" and "Went out" are only used for statistics calculation if the results available for statistics formation show a matching message issued at a preceding time period with the state "Came in". If only one acknowledgment shows up with single-mode acknowledgment or dual-mode acknowledgment, the acknowledgment time for calculation of the cumulated and average duration for both states "Came In/Initial acknowledgment and "Came In/Second acknowledgment" are taken into consideration. If Runtime was deactivated and activated several times and a message was pending during this time, e.g. due to the external discrete alarm or the chronological order alarm, the message is entered multiple times in the archive with the state "Came In" and is also counted several times during calculation.
You have opened the Graphics Designer is opened and linked an Alarm Control | |
You have selected the message blocks you want to incorporate in the hit list on the "Message Blocks" tab. | |
You have specified the properties of the message blocks that you want to incorporate in the hit list. |
You have activated the keyboard function "Hit List" on the "Toolbar" tab of the Alarm Control.
Double-click the Control. Select the "Hit List" tab.
Select the columns you want to display in the hit list. To do so, click . The "Add Columns" dialog opens.
The dialog contains all statistical calculations that are available, as well as a limited number of configured message blocks. You add the columns to the hit list by making one or more selections and clicking "OK". If you want to remove columns from the hit list, select the relevant columns in the "Hit List Columns" list and click
You can change the order in which the columns are displayed in the hit list by selecting the column and clicking
Configure the column properties for the statistics data columns. You can rename the column, change the alignment and the format of the values in the column, and adjust the width of the column.
. Columns can be named in two ways: If you are assigning a column name that is identical every runtime language, enter a name in the edit box. If you want to use multiple languages, use a text entry in the test library. Click to select an existing text ID from the text library.