Place of Origin: | America |
Brand Name: | TYCO |
Certification: | CE |
Model Number: | V23401-H2010-B222 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 10000pcs/week |
TYCO: | TYCO | V23401-H2010-B222: | V23401-H2010-B222 |
---|---|---|---|
America: | America | Color: | Black |
Temperature: | 20-120 | Wire: | Wire |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
V23401-H2010-B222
V23401-H1009-B102
V23401-T2001-B214
V23401-H2001-B214
V23401-T2001-B222
V23401-H2001-B222
V23401-T2001-B201
V23401-H2001-B201
V23401-T2001-B202
V23401-H2001-B202
V23401-T2009-B214
V23401-H2009-B214
V23401-T2009-B222
V23401-H2009-B222
V23401-T2009-B201
V23401-H2009-B201
V23401-T2009-B202
V23401-H2009-B202
V23401-T2010-B214
V23401-H2010-B214
V23401-T2010-B222
V23401-H2010-B222
V23401-T2010-B201
V23401-H2010-B201
V23401-T2010-B202
V23401-H2010-B202
V23401-T2014-B214
V23401-H2014-B214
V23401-T2014-B222
Opens the dialog for selecting a WinCC function. The function must return the Boolean values "TRUE" or "FALSE". Archiving stops as soon as the selected function returns the value "TRUE".
Opens the dialog for selecting a binary tag. Archiving starts as soon as the selected tag has the value "1"
Opens the dialog for selecting a binary tag. Archiving stops as soon as the selected tag has the value "1".
Option activated: The value is archived even if it has not changed in case of a segment change.
Option activated: The value is archived even if it has not changed in case of a segment change.
Input of a value for hysteresis. If a value is input, process values are only archived if they deviate by this value (absolute or relative) from the value archived last.
(only with binary tags) Selection of the signal change that triggers archiving. The option "Always" results in a permanently up-to-date trend display of the value. The value is archived even if there is no signal change.
(only with analog tags) Processing function for the values acquired since the last archiving. The following selections can be made: ● Current value - archives the currently acquired value ● Mean value ● Sum ● Minimum value ● Maximum value ● Action - permits running of a script for processing the archived values ● Difference
Input name of any unit. Action for processing Opens the dialog for selecting a script. The selected script processes the values acquired since the last archiving. Save on error Selection which value is archived in case of an error: last value / substitute value
Input of a factor. The factors define a high and a low limit for display of the tags. Values that violate the high or low limit are not displayed.
Option activated: "Swinging Door algorithm" is applied for effective archiving
Positive integer: Minimum period between two archived values
Positive integer: Maximum period between two archived values
Selection determines type of deviation: absolute / in percent
Positive floating-point number: Absolute or relative value of the deviation that is permitted when calculating the gradient using the algorithm; base value is the last process value saved.
Consistent positive or negative integer: The value range is specified by the high and low limit of the compression distribution; relevant only with relative (in percent) deviation. The input of limit values is deactivated in the case of absolute deviation.
Option activated: Archive tag is considered to be "relevant long term" by the archive server
If you want to be able to change archived values and add new values manually to the archive in Runtime, select "Manual input permitted". If manual input is not permitted, no values can be written to the archive in Runtime from external interfaces such as ODK or OPC, or from WinCC OnlineTableControl.
Enter text as required Last change Display only: Time stamp of last change
Here, the name of the archive containing the configured archive tag is displayed.
Display: Process Tag name Internal name of the archive tag specified after selection of a format DLL. Depending on the format DLL used, IDs can be input for identification of the tags. If an alias is specified as archive tag name, the internal tag name is used for management in the process archive and for addressing the archive tags.
Selection of raw data tag whose values are saved in the archive tag. Archive tag name Alias name of the tag, can be freely edited. Is used instead of the tag name. Format DLL Selection of the format DLL.
Enter text as required. Archiving disabled Option activated: Compressed values are not archived for this tag. Relevant long term Option activated: Archive tag is considered to be "relevant long term" by the archive server. Manual input permitted If you want to be able to change archived values and add new values manually to the archive in Runtime, select "Manual input permitted". If manual input is not permitted, no values can be written to the archive in Runtime from external interfaces such as ODK or OPC, or from WinCC OnlineTableControl. Last change Display only: Time stamp of last change
Name of the compressed tag | |
Selection: Manual / System | |
Option activated:Values changed manually or created in Runtime are taken into consideration. |