Place of Origin: | America |
Brand Name: | TYCO |
Certification: | CE |
Model Number: | V23401-T1005-B102 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Supply Ability: | 10000pcs/week |
TYCO: | TYCO | V23401-T1005-B102: | V23401-T1005-B102 |
---|---|---|---|
COLOR: | BLACK | Material: | Iron |
Temperature: | 20-130 | Wire: | Wire |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
V23401-T1005-B102
V23401-H1009-B122
V23401-T1009-B101
V23401-H1009-B101
V23401-T1009-B102
V23401-H1009-B102
V23401-T2001-B214
V23401-H2001-B214
V23401-T2001-B222
V23401-H2001-B222
V23401-T2001-B201
V23401-H2001-B201
V23401-T2001-B202
V23401-H2001-B202
V23401-T2009-B214
V23401-H2009-B214
V23401-T2009-B222
V23401-H2009-B222
V23401-T2009-B201
V23401-H2009-B201
V23401-T2009-B202
V23401-H2009-B202
V23401-T2010-B214
V23401-H2010-B214
V23401-T2010-B222
V23401-H2010-B222
V23401-T2010-B201
V23401-H2010-B201
Determine the object name of the Alarm Control based on the object properties of the Control, for example, "OLE-Control1". | |
Insert a graphic object from the smart objects of the object palette into the picture. Use the mouse to resize the graphic object to the desired size. In the configuration dialog, select the picture to be displayed, for example, | |
3. In order to make the graphic object dynamic, open the Properties dialog for the object via the shortcut menu of the graphic object. On the "Events" tab, select the "Mouse" object and use a C-Action to make the "Mouse Action" attribute dynamic.
|
In order to enable a single acknowledgement of messages, you must select the "AXC_OnBtnSinglAckn" function from the "Alarm" standard functions group in the "Edit Action" window. To do so, double-click the function.
In the "Edit Action" window, replace the string "lpszObjectName" with the object name of the Alarm Control. In the example, the string is replaced with "OLE-Control1". After successful creation of the action, click "OK" to close the window.
Save your settings in the Graphics Designer. 8. Start Runtime. Click the "Tank 1" button to generate a message. Now, click . The message is acknowledged, and the color of the message changes.
In WinCC Alarm Control, only the SQL statements that can also be generated using the selection dialog of the message window are permitted. The following conditions apply to WinCC: ● The structure consists of "Field", "Operand", and "Value", with the individual parameters separated by blanks. E.g.: DATETIME >= '2006-12-21 00:00:00' AND MSGNR >= 100 (all messages as of 12/21/2006 with a message number greater than and equal to 100) ● Character strings, date, and time must be passed in single quotation marks. ● In the "DATETIME" argument, the date and time of day are separated by a blank. Regardless of the time base setting in the object properties, the output of "DATETIME" is based on the time base "Local Time". The "UTC" setting of the time base is an exception; the output is then based on the "UTC" time base. ● The length of the SQL statement in WinCC AlarmControl is limited to 4096 characters. ● Only the SQL statements that can also be generated using the selection dialog of the message window are permitted.
Message class ID 1-16 and system message classes 17 + 18 - Message type ID 1-256 and system message types 257, 258, 273, 274
Only the arguments indicated in the table and operands from the list are valid. The following are not valid: ● The "OR" operand ● Multiple use of the same "Textxx" argument, e.g. "Text1" ● Grouping of arguments, e.g. by means of parentheses.
WinCC offers the following options: ● Process and archive process values from a plant ● Output process values in the picture or as a log You configure archives in the "Tag Logging" editor. This chapter shows you: ● The basics of process value archiving ● How to configure the process value archiving ● How to output process value