Place of Origin: | America |
Brand Name: | TYCO |
Certification: | CE |
Model Number: | V23401-T2009-B202 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 10000pcs/week |
TYCO: | TYCO | V23401-T2009-B202: | V23401-T2009-B202 |
---|---|---|---|
COLOR: | BLACK | WIRE: | WIRES |
Temperature: | -20-150 |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
V23401-T2009-B202
V23401-T1009-B122
V23401-H1009-B122
V23401-T1009-B101
V23401-H1009-B101
V23401-T1009-B102
V23401-H1009-B102
V23401-T2001-B214
V23401-H2001-B214
V23401-T2001-B222
V23401-H2001-B222
V23401-T2001-B201
V23401-H2001-B201
V23401-T2001-B202
V23401-H2001-B202
V23401-T2009-B214
V23401-H2009-B214
V23401-T2009-B222
V23401-H2009-B222
V23401-T2009-B201
V23401-H2009-B201
V23401-T2009-B202
V23401-H2009-B202
V23401-T2010-B214
V23401-H2010-B214
V23401-T2010-B222
V23401-H2010-B222
V23401-T2010-B201
V23401-H2010-B201
V23401-T2010-B202
V23401-H2010-B202
V23401-T2014-B214
V23401-H2014-B214
V23401-T2014-B222
V23401-H2014-B222
V23401-T2014-B201
V23401-H2014-B202
V23401-T2014-B202
The "Zero Point" attribute specifies for the representation of the bar in which position the zero point value is displayed. The value is specified relative to the spacing of the scale end values in %. For a value of 0 %, for example, the zero point value is shown at the height of the large tick mark with the lowest value. The zero point can also be outside of the range represented. The "Zero Point" attribute is only evaluated if the "Bar Scaling" attribute has the value "Automatic". The absolute value for the zero point is set with the "Zero Point Value" attribute in the "Miscellaneous" property group. There is a free choice of value. The "Zero Point" attribute can be made dynamic with the name "ZeroPoint".
Only Large Tick Marks (LongStrokesOnly) The "Only Large Tick Marks" attribute specifies for the "Bar" object whether the sections between the large tick marks in the scale of the bar are divided by shorter tick marks. The length of the large tick marks is specified with the "Large Tick Marks Length" attribute. The length of the shorter tick marks corresponds to half of the value specified here
In the scale of the bar, only large tick marks are displayed. No In the scale of the bar, the sections between the large tick marks are divided by shorter tick marks. The "Only Large Tick Marks" attribute can be made dynamic with the name "LongStrokesOnly".
The "Scale" attribute specifies for the "Bar" object whether the bar is labeled with a scale. Yes The bar is displayed with a scale. No The bar is displayed without a scale. The "Scale" attribute can be made dynamic with the name "Scaling"
The "Scale Marks" attribute specifies for the "Bar" object the number of segments into which the bar is divided by the large tick marks of the scale.
The "Bar" object can be divided into a maximum of 100 segments. = 0 The optimum number of segments is set automatically. The "Scale Marks" attribute can be made dynamic with the name "ScaleTicks"
The "Digits to the Left of the Decimal Point" attribute specifies for the "Bar" object the number of digits before the decimal point for the display of numerical values in the scale.
The value can be chosen freely within the specified limits. The "Digits to the Left of the Decimal Point" attribute can be made dynamic with the name "LeftComma".
The "Number of Visible Lines" attribute specifies the number of lines displayed in the selection list of a text list. If the amount of configured text is larger than this value, the selection list receives a vertical scroll bar in Runtime. There is a free choice of value. The " Number of Visible Characters" attribute can be made dynamic with the name "NumberLines".
The "Output Format" attribute specifies the format for the display of an output value in the I/O field. The available format definitions depend on the value of the "Data Format" attribute. The following data formats are available for the input and output of values in an I/O field: ● Numerical values can be processed in binary, decimal, or hexadecimal format. ● For the display of text, assign the "String" data format. ● For the "Date/Time" data format, the date and/or time as well as the time span in milliseconds can be displayed. The "Output Format" can be dynamized using the "OutputFormat" name.
The "Output Value" attribute specifies a start value for the output which is displayed in Runtime in the case of a missing process driver connection or if an update has not yet taken place. It must be possible to display the output value with the format specifications specified with the "Output Format" attribute. If this is not the case, three asterisks are displayed instead of the output value. There is a free choice of value. The "Output Value" attribute can be made dynamic with the name "OutputValue".
The "Bit Number" attribute specifies the number of the relevant bit in the output value. | |
The value can be chosen freely within the specified limits. | |
The "Bit Number" attribute can be made dynamic with the name "BitNumber". |