Place of Origin: | America |
Brand Name: | TYCO |
Certification: | CE |
Model Number: | V23401-T2014-B202 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 10000pcs/week |
TYCO: | TYCO | V23401-T2014-B202: | V23401-T2014-B202 |
---|---|---|---|
America: | America | COLOR: | BLACK |
Temperature: | -20-150 | Wire: | 6 Wires |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
V23401-T2014-B202
V23401-H2010-B222
V23401-T2010-B201
V23401-H2010-B201
V23401-T2010-B202
V23401-H2010-B202
V23401-T2014-B214
V23401-H2014-B214
V23401-T2014-B222
V23401-H2014-B222
V23401-T2014-B201
V23401-H2014-B202
V23401-T2014-B202
V23401-T2015-B214
V23401-T2009-B202
V23401-T2002-B209
V23401-T2014-B209
V23401-T2014-E209
V23401-T2099-C502
V23401-H1005-D101
V23401-T1002-B122
V23401-H1002-B101
V23401-T1002-B102
V23401-H1002-B102
V23401-T1005-B114
V23401-H1005-B114
V23401-T1005-B122
V23401-H1005-B122
V23401-T1005-B101
V23401-H1005-B101
V23401-T1005-B102
V23401-H1005-B102
V23401-T1009-B114
V23401-H1009-B114
V23401-T1009-B122
V23401-H1009-B122
V23401-T1009-B101
V23401-H1009-B101
V23401-T1009-B102
V23401-H1009-B102
V23401-T2001-B214
With the default value for "Picture Buffer Size", the list will record the calls for a maximum of 30 pictures. As a rule, it is not reasonable to substantially increase this value, since the switchover can only be done in single steps. You can achieve more efficient screen navigation using picture modules.
Runtime can only be started, when one of the project's process pictures has been defined as the start picture. This start picture will be displayed when Runtime is activated from WinCC Explorer. The start picture is defined on the "Graphics Runtime" tab card in the "Computer properties" dialog.
In the "Start picture" field, enter the name of the desired picture file in the PDL format or click the "Find..." button to select it
Click in the navigation window of the WinCC Explorer with the left-hand mouse button on the entry "Graphics Designer". All pictures of the current project are displayed in the data window (format PDL). 2. Now right click the desired picture and select "Define screen as start screen". The selected picture is entered into the "Start picture" field in the tab "Graphics Runtime".
How to set up Runtime | The pop-up menu in the Data Window |
How to set up Runtime | The pop-up menu in the Data Window |
The pop-up menu in the Data Window | The pop-up menu in the Data Window |
In process pictures with objects arranged in a tabular form, it is possible to define a cursor control to permit mouseless navigation between the configured objects. The shortcut keys for the cursor control and the behavior of the cursor are set on the "Graphics Runtime" tab in the "Computer properties" dialog
Specify how the cursor should react in a table of listed objects, once it has reached the last object in a line or column: This requires all objects are assembled as a complete table. The table cannot have gaps. The height and width of the objects must be identical and the objects must be arranged vertically and horizontally to the exact pixel.
The cursor returns to the first object in the same line or column
The cursor remains positioned on the last object in the line or column.
The cursor continues to the first object in the next line or column.