Place of Origin: | America |
Brand Name: | TYCO |
Certification: | CE |
Model Number: | V23401-T2001-B201 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 10000pcs/week |
TYCO: | TYCO | V23401-T2001-B201: | V23401-T2001-B201 |
---|---|---|---|
America: | America | Color: | Black |
Wire: | 6 Wires | Temperature: | -50-120 |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
V23401-T2001-B201
V23401-T2001-B201
V23401-H1005-D101
V23401-D1001-B122
V23401-D1001-B101
V23401-D1001-B102
V23401-D1008-B114
V23401-D1008-B122
V23401-D1008-B101
V23401-D1008-B102
V23401-D1009-B114
V23401-D1009-B122
V23401-D1009-B101
V23401-D1009-B102
V23401-S1001-B122
V23401-S1001-B101
V23401-S1001-B109
V23401-S1001-B110
V23401-T1002-B114
V23401-H1002-B114
V23401-U2117-C333
V23401-T1002-B122
V23401-H1002-B101
V23401-T1002-B102
V23401-H1002-B102
V23401-T1005-B114
V23401-H1005-B114
V23401-T1005-B122
V23401-H1005-B122
V23401-T1005-B101
V23401-H1005-B101
Open the desired line layout in the line layout editor. 2. Click in the Table area on the Time Base... button. The Time Base Entry dialog is displayed. 3. Select the required time base and confirm with "OK"
In the filter criteria for alarm output, WinCC always uses the time base of the corresponding dynamic object.
The start time and the selected time range of the data to be printed is always shown in local computer time. The start time and the selected time range are not influenced by the time base of the project nor by the time base of a dynamic object.
If the central date and time format in ISO 8601 format is forced in the Computer Properties dialog, this also has an effect on time displays in the reports.
You can edit a project in a single-user system or a multi-user system during Runtime. Remember, however, that some configuration tasks are not possible. WinCC also provides the Load Online Changes function. With the Load Online Changes function, you can edit a project on one computer while it is running on another computer in
Runtime. When configuring with Load Online Changes, there are other restrictions than those that apply to online configuration
For more detailed information on the possibilities for online data editing, refer to the description of the relevant editor in the WinCC Information System. You can edit the following elements while the project is activated in Runtime:
Modifications only become effective in Runtime after the project has been deactivated and Runtime restarted.
Depending on the configuration, a modification in a picture is updated in Runtime after the picture has been reselected. | |
Only possible with external tags when the channel used supports the function. This currently applies only to the S7 channel | |
Only valid when the contained tags can be deleted. |
Only possible if the structure type does not contain structure tags. Edit: Only possible as long as no structure tag has been set up under the structure type
Delete: Only valid when the associated structure tag elements can be deleted. Connections (tag management) Yes Yes Yes Changes to a connection ca
A picture is updated at Runtime only after reselection.
Create/Delete/Edit: Only valid for the Runtime documentation.