Place of Origin: | America |
Brand Name: | TYCO |
Certification: | CE |
Model Number: | V23401-H1009-B114 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 10000pcs/week |
TYCO: | TYCO | V23401-H1009-B114: | V23401-H1009-B114 |
---|---|---|---|
COLOR: | BLACK | Material: | Iron |
Temperature: | -50-120 | Wire: | 6 Wires |
Demention: | 50mm |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
V23401-H1009-B114
V23401-H2009-B201
V23401-T2009-B202
V23401-H2009-B202
V23401-T2010-B214
V23401-H2010-B214
V23401-T2010-B222
V23401-H2010-B222
V23401-T2010-B201
V23401-H2010-B201
V23401-T2010-B202
V23401-H2010-B202
V23401-T2014-B214
V23401-H2014-B214
V23401-T2014-B222
V23401-H2014-B222
V23401-T2014-B201
V23401-H2014-B202
V23401-T2014-B202
V23401-T2015-B214
V23401-T2009-B202
V23401-T2002-B209
V23401-T2014-B209
V23401-T2014-E209
V23401-T2099-C502
V23401-H1005-D101
V23401-T1002-B122
V23401-H1002-B101
V23401-T1002-B102
V23401-H1002-B102
V23401-T1005-B114
V23401-H1005-B114
V23401-T1005-B122
V23401-H1005-B122
V23401-T1005-B101
V23401-H1005-B101
V23401-T1005-B102
V23401-H1005-B102
V23401-T1009-B114
V23401-H1009-B114
V23401-T1009-B122
V23401-H1009-B122
V23401-T1009-B101
When an OS project is created in the PCS 7 ES, the OS Project Editor is called automatically and initialized with default settings with reference to the runtime system and the message system. Only if you want a configuration other than the default configuration do you have to start the OS Project Editor in the WinCC Explorer and configure your desired project settings. If you create a new WinCC project with Basic Process Control, you must start the OS Project Editor. The OS Project Editor must run before the User Administrator is opened, otherwise the User Administrator will be initialized with the authorization levels of WinCC. The OS Project Editor creates the picture construction in overview area, work area, and button area as well as basic data in the WinCC server or client projects. The areas in the picture hierarchy are displayed automatically in the overview area of Runtime. In Runtime, the Split Screen Manager manages the display data, the picture compositions, and the picture changes according to the picture hierarchy. The picture change is configured with the standard functions of the Split Screen Manager. All necessary data for the message configuration and the message display is created by the OS Project Editor. There is no need to configure a WinCC Alarm Control. You can change the default settings for display of the message system on the operator station in the OS Project Editor. WinCC Explorer displays the system pictures contained in the basic data with "@" prefix at the "Graphics Designer" editor. You can hide the system pictures in WinCC Explorer. Select the "Graphics-Runtime" tab in the properties dialog of the computer and activate the "Use prefix" option in the "Hide system pictures" field. The text field on the right must contain .
To ensure time synchronization for all operator stations, you have to configure the time synchronization using the "Time Synchronization" editor for every operator station.
Define project type | |
if required, enter the name of the configuration engineer, the project version, and a commenti | |
Specify the project name and project folder |
The lifebeat monitoring function monitors functionality of all automation systems and operator stations and creates a process control message, if necessary. You configure the lifebeat monitoring in WinCC using the "Lifebeat Monitoring" editor.
The "Horn" editor is used to control optical and acoustic signaling devices or the output from audio files when messages come in.
The "Picture Tree Manager" is used to manage a hierarchy of systems, subsystems and Graphics Designer pictures. Using the Picture Tree Manager, the hierarchy of the group displays can also be recalculated or updated.