Home ProductsTYCO

TYCO V23401-T2679-C302 V23401-T2679-C302 V23401-T2679-C302 V23401-T2679-C302

TYCO V23401-T2679-C302 V23401-T2679-C302 V23401-T2679-C302 V23401-T2679-C302

    • TYCO V23401-T2679-C302 V23401-T2679-C302 V23401-T2679-C302 V23401-T2679-C302
    • TYCO V23401-T2679-C302 V23401-T2679-C302 V23401-T2679-C302 V23401-T2679-C302
    • TYCO V23401-T2679-C302 V23401-T2679-C302 V23401-T2679-C302 V23401-T2679-C302
  • TYCO V23401-T2679-C302 V23401-T2679-C302 V23401-T2679-C302 V23401-T2679-C302

    Product Details:

    Place of Origin: America
    Brand Name: TYCO
    Certification: CE
    Model Number: V23401-T2679-C302

    Payment & Shipping Terms:

    Minimum Order Quantity: 1PCS
    Packaging Details: CARTON
    Delivery Time: IN STOCK
    Payment Terms: T/T, Western Union, MoneyGram
    Supply Ability: 10000pcs/week
    Contact Now
    Detailed Product Description
    Material: Iron TYCO: TYCO
    Diameter: 50mm Temperature: 20-120
    WIRE: 6 WIRES COLOR: BLACK

     

     We can sell the products of TYCO at a advantage price

    Guang Zhou Lai Jie Electric Co.,LTD

    Please contact with “Tommy” for the price

    V23401-T2679-C302

    V23401-T1005-B122

    V23401-H1005-B122

    V23401-T1005-B101

    V23401-H1005-B101

    V23401-T1005-B102

    V23401-H1005-B102

    V23401-T1009-B114

    V23401-H1009-B114

    V23401-T1009-B122

    V23401-H1009-B122

    V23401-T1009-B101

    V23401-H1009-B101

    V23401-T1009-B102

    V23401-H1009-B102

    V23401-T2001-B214

    V23401-H2001-B214

    V23401-T2001-B222

    V23401-H2001-B222

    V23401-T2001-B201

    V23401-H2001-B201

    V23401-T2001-B202

    V23401-H2001-B202

    V23401-T2009-B214

    V23401-H2009-B214

    V23401-T2009-B222

    V23401-H2009-B222

    V23401-T2009-B201

    TYCO V23401-T2679-C302 V23401-T2679-C302 V23401-T2679-C302 V23401-T2679-C302

     

    Input impedance
    Tolerance: ± 15 %

     

    Data_Exchange The slave now will react exclusively to the master it was parameterized and configured by. The master transmits a user data request (Data_Exchange), the slave responds by a user data response informing the master about any current diagnostic events. The slave provides the true diagnosis and status information only after the master’s diagnosis telegram.

    Diagnostic request by master The master transmits a Slave Diagnose Request (Slave_Diag), the slave responds by a Slave Diagnose Response. This way, the master verifies whether the slave exists in the bus and is ready for parameterization and configuration.

    GSD file The device master data file (GSD file) describes all encoder data required for operation. Format and content are defined by standard EN 50170. The GSD file provides ident number 09F6 for all encoders described. The GSD file is an essential configuration tool for encoder parameterization and configuration.

     

    PROFIBUS is a manufacturer-unspecific open communication system for applications in the fields of production, process and building automation. It is broken down into three variants: PROFIBUS FMS for data communication between control units on the production and process management level. PROFIBUS PA for process engineering applications. PROFIBUS DP for fast data exchange between control units and decentralized peripherals in process automatio

     

    Readout of block 0 of I&M functions (I&M0) is in line with PROFIBUS Identification & Maintenance Guideline 3502 and DPV2 encoder profile 3162. Data blocks I&M1 to I&M4 are not implemented. I&M functions are accessed by Slot 0 or Slot 1 and index 255. Access to block I&M0 is by parameter number 65000 (0xFDE8). Slot 0 of SIEMENS controls is addressed by the diagnosis address of the DP slave, in the example below 4093 (0x0FFD)

     

    Input impedance
    Tolerance: ± 15 %

    ofile parameter 65000 preset value This parameter is to read or write the preset value the encoder is set to upon having accomplished the preset command using output data word G1_STW1, bit „PR“. The preset value is not automatically saved (see parameter 971 to save). Note: It goes without saying that the absolute encoder position will remain also during power off and at power on, even if the encoder received a preset command before.

    Readout of data block „Sensor Format“. The data block informs on sensor parameters as sensor type, programmed singleturn resolution, shift factor for G1_XIST1 and G1_XIST2 as well as the number of possible turns (multiturn encoders). This information can also be called up individually utilizing the sub indexes. The example shows how to call all elements of an encoder with a parameterized resolution of 8192 steps/revolution, revolution counter 65536 revs. (in this case 0xFFFF). Left-aligned display in G1_XIST1 by shift factor =3.

    PROFIdrive parameter 971 transfer to non-volatile memory By calling this parameter all volatile parameter are stored into the encoder’s non-volatile memory. At the present DPV2 encoder this procedure relates only to the preset value (profile parameter 65000). The saving operation is performed in DS_WRITE.

    PROFIdrive parameter 964 device ID Readout of the device ID (device identification data). This data block provides information on manufacturer, device name, firmware version and firmware date. This information can be called up individually utilizing the sub indexes.

    TYCO V23401-T2679-C302 V23401-T2679-C302 V23401-T2679-C302 V23401-T2679-C302

     

    Contact Details
    Guang Zhou Lai Jie Electric Co.,Ltd

    Contact Person: Mr. Tommy

    Tel: 86-020-87268766

    Fax: 86-020-87269099

    Send your inquiry directly to us (0 / 3000)