Place of Origin: | GERMANY |
Brand Name: | LENZE |
Certification: | CE |
Model Number: | E94ASHE1454 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
LENZE: | LENZE | E94ASHE1454: | E94ASHE1454 |
---|---|---|---|
Material: | Iron | GERMANY: | GERMANY |
Temperature: | 20-90 | Color: | Black |
Dimension: | 80mm |
communication to a maximum value. You flatten peaks in the data feed. |
|
You share the remaining bandwidth based on demand. Display and Web serveBacking up and restoring via the displayr |
You can back up and restore the CPU configuration to/from the SIMATIC memory card without a programming device/PC. |
Backing up and restoring via the display |
You can make a backup copy of an operational
project without STEP 7 (TIA Portal).
In an "emergency", you can simply use an existing
configuration without STEP 7 (TIA Portal), for
example, during commissioning or after a program
download.Display and Web
server provide up to
three project languages
for comments
and message texts
When you export your plants worldwide, for
example, comments or message texts can be
stored on the card in up to 3 languages. For
example, German - the language of the author,
English - readable internationally, Portuguese
- language of the end user.
You provide customers with better service.
Trace via Web server When you enable trace functions via the Web
server, you have better service support. You
can send your trace recordings to your service
partner via Web service, for example.
You receive plant/project information for diagnostics
and maintenance requirements without
STEP 7 (TIA Portal).
You can provide trace recordings via the Web
server.
You save time in troubleshooting.
Monitoring of configured
technology objects
via a Web server
You can monitor states, errors, technology
alarms and the current values of technology
objects with the Web server.
Formatting, deleting
or converting a
SIMATIC memory
card via the display
Without the method using STEP 7 (TIA Portal), your SIMATIC memory card is formatted, deleted
or converted into a program card directly via the display. You save time.
Motion Control
Greater number of
axes for Motion Control
applications and
new technology objects:
Output cam,
cam track and probe
Speed specification for, for example:
• Pumps, fans, mixers
• Conveyor belts
• Auxiliary drives
Positioning tasks, such as:
• Lifting and vertical conveyors
• Feeding and gate control
• Palletizing equment
Output cams and cam tracks make other applications
possible, for example:
• Applying glue tracks
• Triggering switching operations with precise
positioning
• Very precise processing of products on a
conveyor belt
Operate probe. e.g.:
• For measuring products
• For detecting the position of the product on
a conveyor belt
You can implement additional Motion Control
applications with a CPU.
You can implement numerous applications using
the scalability in the configuration limits.
High machine speeds result in greater productivity
with better accuracy.
Support of the value
status (QI) for digital
and analog on-board
I/O
You can use the value status to evaluate
whether the input and output data is correct
and react accordingly in the user program in
the case of error, for example sk specific
program sequences.
In the user program, you can respond quickly and
easily to faults and errors.The SIMATIC is the modular control system for numerous automation applications
in discrete automation.
The modular and fanless design, the simple implementation of distributed structures and the
user-friendly handling transform the SIMATIC into a cost-effective and convenient
solution for a wide variety of tasks.
Application area of the SIMATIC are for example:
● Special-purpose machines
● Textile machinery
● Packaging machines
● General mechanical engineering
● Controller engineering
● Machine tool engineering
● Installation engineering
● Electrical industry and crafts
● Automotive
● Water/waste water
● Food & Beverage
Application area of the SIMATIC T are for example:
● Packaging machines
● Converting application
● Assembly automation
Several CPUs with various levels of performance and a comprehensive range of modules
with many convenient functions are available. Fail-safe CPUs enable use in fail-safe
applications. The modular design allows you to use only the modules that you need for your
application. The controller can be retrofitted with additional modules at any time to expand its
range of tasks.
The high EMC and high resistance to shock and vibration stress make the SIMATIC
suitable for universal use.The compact CPUs can be used for smaller to medium-sized applications and have an
integrated analog and digital on-board I/O as well as integrated technology functions. The
following table shows the differences in performance between the two compact CPUs.
Table 2- 6 Performance overview of compact CPUs
CPU 1511C-1 PN CPU 1512C-1 PN
PROFIBUS interfaces -- --
PROFINET interfaces 1 1
Work memory (for program) 175 KB 250 KB