interconnections of the outputs of front connector X11 to allow you to correctly distribute the available outputs over |
|
the possible technology channels HSC, PWM and PTO. This overview is a combination of interconnection options of technology channels for HSC, PWM and PTO.With sourcing outputs, i |
|
must be taken into consideration that falling edges can be delayed as compared to rising edges depending on the load. |
output if the load at
the output is greater than 240 Ω.
2) The frequency has a basic accuracy of ±100 ppm with a resolution of 0.3638 mHz.
3) Standard outputs are affected by jitter during generation of frequencies. The set period duration is not adhered to in
every period, but it is adhered to on average over several periods.The addresses are divided into five analog input channels and two analog output channels.
STEP 7 (TIA Portal) assigns the addresses automatically. You can change the addresses in
the hardware configuration of STEP 7 (TIA Portal), i.e. freely assign the start address. The
addresses of the channels are based on the start address.
"IB x", for example, stands for the start address input byte x. "QB x" stands, for example, for
the start address output byte x.As of firmware version 2.0, the analog and digital on-board I/O support the value status as
diagnostics option. You activate the use of the value status in the hardware configuration of
STEP 7 (TIA Portal). Value status is deactivated by default.
When you activate the value status, the input area of the analog on-board I/O contains two
additional bytes, which provide the QI bits to the five analog input channels and two analog
output channels. You access the QI bits through the user program.
Value status of input channels
Value status = 1 ("Good") indicates that the value of the assigned input at the terminal is
valid.
Value status = 0 ("Bad") indicates that the read value is not valid.
Possible cause for value status = 0:
● A channel has been deactivated
● A measured value was not updated after a parameter change
● A measured value is outside the low/high measuring range (overflow/underflow)
● Wire break has occurred (only for the "Voltage" measurement type in the measuring
range "1 to 5 V" and for the "Current" measurement type in the measuring range "4 to
20 mA")
Value status of output channels
The value status = 1 ("Good") indicates that the process value specified by the user program
is correctly output at the terminal.
The value status = 0 ("Bad") indicates that the process value output at the hardware output is
incorrect.
Possible cause for value status = 0:
● A channel has been deactivated
● Outputs are inactive (for example, CPU in STOP)
● An output value is outside the high/low measuring range (overflow/underflow)
● Wire break has occurred (only for the "Current" output type)
● Short-circuit has occurred (only for the "Voltage" output type)The addresses are divided into 16 digital input channels and 16 digital output channels.