Place of Origin: | GERMANY |
Brand Name: | LENZE |
Certification: | CE |
Model Number: | EVS9324-ES |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
LENZE: | LENZE | EVS9324-ES: | EVS9324-ES |
---|---|---|---|
GERMANY: | GERMANY | Material: | Iron |
Color: | Black | Temprerature: | 20-90 |
Dimension: | 70mm |
Security Integrated In conjunction with STEP 7, each CPU offers password-based know-how protection against unauthorized reading out or modification of the program blocks. |
|
Copy protection provides reliable protection against unauthorized reproduction of program blocks. With copy protection |
|
individual blocks on the SIMATIC memory card can be tied to its serial number so that the block can only be run if the configured memory card is inserted into the CPU. |
In addition, you can assign various access rights to different user groups in the controller
using four different authorization levels.
Improved manulation protection allows changed or unauthorized transfers of engineering
data to be detected by the controller.
The use of an Ethernet CP (CP 1543-1) provides the user with additional access protection
through a firewall or possibilities to establish secure VPN connectionsThe fail-safe CPUs are intended for users who want to implement demanding standard and
fail-safe applications both centrally and decentrally.
These fail-safe CPUs allow the processing of standard and safety programs on a single
CPU. This allows fail-safe data to be evaluated in the standard user program. The integration
thereby provides the system advantages and the extensive functionality of SIMATIC for
fail-safe applications.
The fail-safe CPUs are certified for use in safety mode up to:
● Safety class (Safety Integrity Level) SIL 3 according to IEC 61508:2010
● Performance Level (PL) e and Category 4 according to ISO 13849-1:2006 or according to
EN ISO 13849-1:2008
Additional password protection for F-configuration and F-program is set up for IT security.
In addition to the CPUs, further components such as SINAMICS drives dispose of integrated
safety functions. Additional information about integrated safety functions in drives can be
found in the manuals for the respective products.All CPUs of the SIMATIC product series feature a display with plain text
information. The display provides the user with information on the order numbers, firmware
version, and serial number of all connected modules. In addition, the address of the CPU
and other network settings can be adapted locally without a programming device. Error
messages are immediately shown on the display in plain text. In the case of servicing, plant
downtimes are minimized by quick access to diagnostics alarms. Detailed information about
this and a multitude of other display functions is available in the SIMATIC Display Uniform front connectors for all modules and integrated potential bridges for flexible
formation of potential groups simplifies storage. Additional components such as circuit
breakers, relays, etc., can be installed quickly and easily, since a DIN rail is implemented in
the rail of the . The CPUs of the SIMATIC product series can be expanded
centrally and in a modular fashion with signal modules. Space-saving expansion enables
flexible adaptation to each application.
The system cabling for digital signal modules enables fast and clear connection to sensors
and actuators from the field (fully modular connection consisting of front connector modules,
connection cables and I/O modules), as well as easy wiring inside the control cabinet
(flexible connection consisting of front connectors with assembled single conductors)Integrated system diagnostics is activated by default for the CPUs. The different types of
diagnostics are configured instead of programmed. System diagnostics information is shown
uniformly and in plain text on the display of the CPU, in STEP 7, on the HMI and on the Web
server, even for alarms related to drives. This information is available in RUN mode, but also
in STOP mode of the CPU. The diagnostic information is updated automatically when you
configure new hardware components.
The CPU is available as a central interrupt server in up to three project languages. The HMI
takes over the display in the project languages specified for the CPU. If you require message
texts in additional languages, you can load these via the configured connection to your HMI.
The CPU, STEP 7 and your HMI guarantee data consistency without additional engineering
steps. The maintenance work is easier.All CPUs of the SIMATIC product series feature a
display with plain text information. The display provides
information on order numbers, firmware version and serial
numbers of all connected modules. In addition, you can set
the address of the CPU and carry out further network
settings. The display shows occurring error messages
directly in plain text.
In addition to the functions listed here, a multitude of other
functions that are described in the SIMATIC Display
Simulator are shown on the display.The 24 V DC supply voltage is supplied via a 4-pole connection
plug that is located at the front of the CPU.
• Chapter Wiring (Page 29)
• , ET 200MP system
manual The interface has two ports. In addition to basic PROFINET
functionality, its also supports PROFINET IO RT (real time)
and IRT (isochronous real time).
PROFINET function manual
(https://support.industry..co
m/cs/ww/en/view/49948856)
Operation of the
CPU as
• IO controller
• I-device