Home ProductsMegger

LENZE EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW

LENZE EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW

    • LENZE EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW
    • LENZE EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW
    • LENZE EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW
    • LENZE EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW
  • LENZE EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW

    Product Details:

    Place of Origin: GERMANY
    Brand Name: LENZE
    Certification: CE
    Model Number: EVF9324-EV 3.0kW

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Packaging Details: carton
    Delivery Time: in stock
    Payment Terms: T/T, Western Union, MoneyGram
    Supply Ability: 100pcs/week
    Contact Now
    Detailed Product Description
    LENZE: LENZE EVF9324-EV 3.0kW: EVF9324-EV 3.0kW
    Material: Iron Color: Black
    Temperature: 20-90 Dimension: 80mm

    LENZE EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kWLENZE EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kWLENZE EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kWLENZE EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW EVF9324-EV 3.0kW

    is output at the digital output. The on-load factor is the relationsh of the pulse duration to
    the cycle duration. In PWM mode, you can control the on-load factor and the cycle duration.
     
    With pulse width modulation, you vary the mean value of the output voltage. Depending on
    the connected load, you can control the load current or the power with this
     
    You can specify the pulse duration as one-hundredth of the period duration (0 to 100), as
    one-thousandth (0 to 1 000), as one ten-thousandth (0 to 10 000) or in S7 analog format.
    ① Period duration
     

    Pulse duration
    The pulse duration can be between 0 (no pulse, always off) and full scale (no pulse, period
    duration always on).
    The PWM output can, for example, be used to control the speed of a motor from standstill to
    full speed or you can use it to control the position of a valve from closed to completely open.
    You configure the pulse width modulation (PWM) mode in STEP 7 (TIA Portal).
    The pulse width modulation mode has the following functions:
    ● When the option "High-speed output (0.1 A)" is activated, you can generate a minimum
    pulse duration of 2 μs at a current of 100 mA. If the option "High-speed output (0.1 A)" is
    not activated, you can generate a minimum pulse duration of 20 μs with a load > 0.1 A
    and a minimum pulse duration of 40 μs with a load of ≥ 2 mA and a current of maximum
    0.5 A. If a standard output is used, you can generate a minimum pulse duration of 100 µs
    with a load of > 0.1 and a minimum pulse duration of 200 µs with a load of ≥ 2 mA.
    ● You can control the pulse output (DQA) of the channel manually via the control and
    feedback interface.
    ● You can configure the reaction to CPU STOP. Upon change to CPU STOP, the pulse
    output (DQA) is set to the configured state.For the pulse width modulation (PWM) mode, the user program directly accesses the control
    and feedback interface of the channel.
    Reconfiguration via the instructions WRREC/RDREC and parameter assignment data record
    128 is supported. You can find additional information in section Parameter data records
    (PWM) (Page 167).
    You control the on-load factor (pulse-cycle ratio) of the pulse width via the OUTPUT_VALUE
    field of the control interface. Pulse width modulation generates continuous pulses based on
    this value. The period duration is adjustable.The control program must output the enable for the output sequence with the help of the
    software enable (SW_ENABLE 0 → 1). The feedback bit STS_SW_ENABLE indicates that
    the software enable is pending at the PWM.
    If the software enable is activated (rising edge), STS_ENABLE is set. The output sequence
    runs continuously, as long as SW_ENABLE is set.
    Note
    Output control signal TM_CTRL_DQ
    • If TM_CTRL_DQ = 1, the technology function takes over the control and generates pulse
    sequences at the output PWM DQA.
    • If TM_CTRL_DQ = 0, the user program takes over the control and the user can set the
    output PWM DQA directly via the control bit SET_DQADeactivating the software enable (SW_ENABLE = 1 → 0) cancels the current output
    sequence. The last period duration is not completed. STS_ENABLE and the digital output
    PWM DQA are immediately reset to 0.
    A renewed pulse output is only possible after a restart of the output sequence.
    Minimum pulse duration and minimum interpulse period
    You assign the minimum pulse duration and the minimum interpulse period with the
    parameter "Minimum pulse duration".
    ● A pulse duration determined by the technology function or PWM channel which is shorter
    than the minimum pulse duration will be suppressed.
    ● A pulse duration determined by the technology function or PWM channel which is longer
    than the cycle duration less the minimum interpulse period will be set to the value of the
    cycle duration (output switched on permanentlyOUTPUT_VALUE assigns the on-load factor for the current period duration. You select the

    Contact Details
    Guang Zhou Lai Jie Electric Co.,Ltd

    Contact Person: Mr. Tommy

    Tel: 86-020-87268766

    Fax: 86-020-87269099

    Send your inquiry directly to us (0 / 3000)