Place of Origin: | GERMANY |
Brand Name: | LENZE |
Certification: | CE |
Model Number: | EVF9325-EV |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
LENZE: | LENZE | EVF9325-EV: | EVF9325-EV |
---|---|---|---|
GERMANY: | GERMANY | Material: | Iron |
Color: | Black | Temperature: | 20-90 |
Dimension: | 80mm | Wire: | Wire |
range of the field OUTPUT_VALUE of the control interface with the "Output format" parameter. |
|
Output format 1/100: Value range between 0 and 100 Pulse duration = (OUTPUT_VALUE/100) x period duration. |
|
Output format 1/1000: Value range between 0 and 1 000 Pulse duration = (OUTPUT_VALUE/1 000) x period duration. |
Output format 1/10000: Value range between 0 and 10 000
Pulse duration = (OUTPUT_VALUE/10 000) x period duration.
● Output format "S7 analog output": Value range between 0 and 27 648
Pulse duration = (OUTPUT_VALUE/27 648) x period duration.
You assign OUTPUT_VALUE directly via the control program. A new OUTPUT_VALUE is
applied at the output when the next rising edge occurs.
Setting and changing the period duration
● Permanent update
The period duration is permanently controlled via the control interface. The MODE_SLOT
bit must be set ("1" means permanent update); LD_SLOT must be set to value 1 ("1"
means period duration). Set the period value in the field SLOT. The unit is always a
microsecond.
– High-speed output activated: between 10 μs and 10 000 000 μs (10 s) in the field
SLOT
– High-speed output deactivated: between 100 μs and 10 000 000 μs (10 s) in the field
SLOT
– Standard output (100 Hz output): between 10 000 µs (10 ms) and 10 000 000 µs
(10 s) in the field SLOT
● Individual updating
Set the period duration in the configuration parameters. Alternatively, execute an
individual update via the control interface. MODE_SLOT must be deleted ("0" means
individual update); LD_SLOT must be set to value 1 ("1" means period duration). Set the
period duration value in the field SLOT. The unit is always a microsecond.
– High-speed output activated: between 10 μs and 10 000 000 μs (10 s) in the
parameters
– High-speed output deactivated: between 100 μs and 10 000 000 μs (10 s) in the
parameters
– Standard output (100 Hz output): between 10 000 µs (10 ms) and 10 000 000 µs
(10 s) in the parameters
The new period duration is applied at the next rising edge of the output.You assign the minimum pulse duration and the minimum interpulse period as DWORD
numerical value between 0 and 10 000 000 μs (10 s) with the help of the channel parameter
configuration "Minimum pulse duration".
eaction to CPU
STOP
The parameter "Output substitute
value" generates a substitute
value upon CPU STOP, which you
can define with the parameter
"Substitute value for pulse output
(DQA)".
Output substitute value Output substitute
value
On CPU STOP, the parameter
"Continue" still generates the
PWM output signal which was
generated before the CPU STOP.
Continue
Substitute value
for pulse output
(DQA)
If you have set the option "Output
substitute value" for "Reaction to
CPU STOP", the parameter "Substitute
value for pulse output
(DQA)" defines the substitute
value to be used for the pulse
output of the channel.
If you have set the option "Continue"
for "Reaction to CPU STOP",
the parameter "Substitute value for
pulse output (DQA)" cannot be
selected.
0
(use substitute value 0)
0
1
(use substitute value 1)
Diagnostics
interrupt
No supply voltage
L+
The parameter "Missing supply
voltage L+" activates the diagnostic
interrupt of the channel in the
case of no supply voltage L+
Deactivated Deactivated
Activated
Parameter High-speed output
(0.1 A)
The "High-speed output (0.1 A)"
parameter is used to specify
whether you want to use the selected