High-speed output deactivated: between 100 μs and 10 000 000 μs (10 s) in the field SLOT |
|
Standard output (100 Hz output): between 10 000 µs (10 ms) and 10 000 000 µs (10 s) in the field SLOT |
|
Individual updating Set the period duration in the configuration parameters. Alternatively, execute an |
individual update via the control interface. MODE_SLOT must be deleted ("0" means
individual update); LD_SLOT must be set to value 1 ("1" means period duration). Set the
period duration value in the field SLOT. The unit is always a microsecond.
– High-speed output activated: between 10 μs and 10 000 000 μs (10 s) in the
parameters
– High-speed output deactivated: between 100 μs and 10 000 000 μs (10 s) in the
parameters
– Standard output (100 Hz output): between 10 000 µs (10 ms) and 10 000 000 µs
(10 s) in the parameters
The new period duration is applied at the next rising edge of the output.The parameter "Output substitute
value" generates a substitute
value upon CPU STOP, which you
can define with the parameter
"Substitute value for pulse output
(DQA)".
Output substitute value Output substitute
value
On CPU STOP, the parameter
"Continue" still generates the
PWM output signal which was
generated before the CPU STOP.
Continue
Substitute value
for pulse output
(DQA)
If you have set the option "Output
substitute value" for "Reaction to
CPU STOP", the parameter "Substitute
he "High-speed output (0.1 A)"
parameter is used to specify
whether you want to use the selected
pulse output as high-speed
output. The requirement for this is
that the selected pulse output
supports operation as high-speed
output.
Deactivated
The output supports frequencies
of up to 10 kHz (load dependent)
and currents of up to 0.5 A or
frequencies of up to 100 Hz and
currents of up to 0.5 A depending
on the performance capability of
the selected output.
Deactivated
Activated
The output supports frequencies
of up to 100 kHz and currents of
up to 0.1 A.
Output format Defines the format of the ratio
value (on-load factor) in the field
"OUTPUT_VALUE" of the control
interface of the channel.
S7 analog output
Interprets the ratio value in the
field OUTPUT_VALUE" of the
control interface as 1/27648 of
the current period duration.
Supported value range from 0 to
27 648
1/100
1/100
Interprets the ratio value in the
field "OUTPUT_VALUE" of the
control interface as percentage
value of the current period duration.
Supported value range 0 to 100
1/1000
Interprets the ratio value in the
field "OUTPUT_VALUE"of the
control interface as a one-tenth
percentage point of the current
period duration.
Supported value range from 0 to
1 000
1/10000
Interprets the ratio value in the
field "OUTPUT_VALUE" of the
control interface as a onehundredth
percentage point of the
current period duration.
Supported value range from 0 to
10 000
Minimum pulse
duration
Defines the minimum pulse duration
and the minimum interpulse
period of the output signal of the
channel. The channel suppresses
all pulses and pauses that are
below the specified value.Defines the pe
value for pulse output
(DQA)" defines the substitute
value to be used for the pulse
output of the channel.
If you have set the option "Continue"
for "Reaction to CPU STOP",
the parameter "Substitute value for
pulse output (DQA)" cannot be
selected.
0
(use substitute value 0)
0
1
(use substitute value 1)
Diagnostics
interrupt
No supply voltage
L+
The parameter "Missing supply
voltage L+" activates the diagnostic
interrupt of the channel in the
case of no supply voltage L+