Place of Origin: | GERMANY |
Brand Name: | LENZE |
Certification: | CE |
Model Number: | E94ASHE0044 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
LENZE: | LENZE | E94ASHE0044: | E94ASHE0044 |
---|---|---|---|
GERMANY: | GERMANY | Material: | Iron |
Color: | Black | Temperature: | 20-90 |
Wire: | Wire |
Figure 2-4 View of the CPU 1511-1 PN (without front panel) - fronThe assignment corresponds to the Ethernet standard for an RJ45 plug. | tself has a MAC address, and each of the two PROFINET ports has its own MAC address. The CPU 1511-1 PN therefore has three MAC addresses in total. |
When autonegotiation is activated, autocrossing is in effect and the RJ45 socket is allocated either as data terminal equment (MDI) or a switch (MDI-X)The CPU 1511-1 PN has a |
The MAC addresses of the PROFINET ports are needed for the LLDP protocol, for example for the neighborhood discovery function. |
PROFINET interface with two ports. The PROFINET interface | The number range of the MAC addresses is sequential. The first and last MAC address are lasered on the rating plate on the right side of each CPU 1511-1 PN. |
he table below shows how the MAC addresses are assigned.
Table 3- 1 Assignment of the MAC addresses
Assignment Labeling
MAC address 1 PROFINET interface X1
(visible in STEP 7 for accessible
devices)
• Front, lasered
• Right side, lasered
(start of number range)
MAC address 2 Port X1 P1 R (required for LLDP,
for example)
• Front and right side, not lasered
MAC address 3 Port X1 P2 R (required for LLDP,
for example)
• Front, not lasered
• Right side, lasered
(end of number range)The status and error displays of the CPU 1511-1 PN are described below.
You will find additional information on "Interrupts" in the STEP 7 online help.
You can find additional information on the topics of "Diagnostics" and "System alarms" in theThe CPU 1511-1 PN has three LEDs to signal the current operating status and diagnostics
status. The following table shows the meaning of the various combinations of colors for the
RUN/STOP, ERROR and MAINT LEDs.Each port has a LINK RX/TX LED. The table below shows the various "LED scenarios" of
ports for the CPU 1511-1 PN.
Table 4- 2 Meaning of the LEDs
LINK TX/RX LED Meaning
LED off
There is no Ethernet connection between the PROFINET interface of the
PROFINET device and the communication partner.
No data is currently being sent/received via the PROFINET interface.
There is no LINK connection.
LED flashes green
The "LED flashing test" is being performed.
LED lit green
There is an Ethernet connection between the PROFINET interface of your
PROFINET device and a communication partner.
LED flickers yellow
Data is currently being received from or sent to a communications partner
on Ethernet via the PROFINET interface of the PROFINET device.Application authentication Yes
• Security Policies Available Security Policies: None,
Basic128Rsa15, Basic256Rsa15,
Basic256Sha256
• User authentication "Anonymous" or with user name and password
Additional protocols
MODBUS Yes; MODBUS TCP
Media redundancySwitchover time in the case of cable break, typ. 200 ms; with MRP; bumpless with MRPD
Number of devices in the ring, max. 5Isochronous mode
Isochronous mode (application synchronized up tterminal)
Yes; with minimum OB 6x cycle of 625 Constant bus cycle time Yes
S7 signaling functionsNumber of stations that can be logged in for signaling
functions, max.
32Block-related alarms Yes
Number of configurable interrupts, max. 5000Number of simultaneously active interrupts in
interrupt pool• Number of reserved user interrupts 300
• Number of reserved interrupts for system diagnostics100
• Number of reserved interrupts for motion control
technology objects
80