Place of Origin: | GERMANY |
Brand Name: | LENZE |
Certification: | CE |
Model Number: | E82EV552k4B |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
LENZE: | LENZE | E82EV552k4B: | E82EV552k4B |
---|---|---|---|
Germany: | Germany | Color: | Black |
Material: | Iron | Temperature: | 20-90 |
Dimension: | 80mm |
ollowing section, you will create the input and output modules for ET 200MP. Procedure 1. Open the device view of ET 200MP. |
Open the "DQ" and "DQ16 x DC24V / 0.5A ST" folders. 5. Drag-and-drop output module "6ES7 522-1BH00-0AB0" to slot 3 of the rail. Result |
Open the "DI" and "DI16 x DC24V HF" folders in the hardware catalog. | ou have created the input and output modules. the following section, you will assign project-specific names to the distributed I/O. |
Drag-and-drop input module "6ES7 521-1BH00-0AB0" to slot 2 of the rail. | Procedure 1. Select ET 200SP. 2. Under Properties > General in the inspector window, enter the name |
"Valve_Control_Unit" in the "Name" field.
3. Select ET 200MP and enter the new name "Mixer_Conveyor_Control_Unit".
Result
You have assigned the project-specific names.obal libraries are used to store elements that you want to reuse in other projects. You must
create global libraries explicitly.
The following libraries are provided in the standard package:
● "Buttons and Switches"
In the following section, you will delete the automatically generated "Main [OB1]" program
block from the project folder. A "Main [OB1]" program block is included in the program blocks
of the example project.
Organization blocks (OBs) form the interface between the CPU operating system and the
user program. These blocks are called by the operating system. At least one cycle OB must
be available in an automation project.
Procedure
1. Open the "Program blocks" folder in the project tree and then click the "Main [OB1]"
program block.
2. Right-click to open the shortcut menu and then click "Delete".
3. Click "Yes" to confirm deletion of the block.
Result
The automatically generated "Main [OB1]" program block is deletedIn the following section, you will insert the program blocks from the
"ProgLib_ColorFillingStation" global library into your project.
Procedure
1. Click on global library "ProgLib_ColorFillingStation".
2. Click the "Master copies" folder and then on "Programm_blocks".
3. Drag-and-drop the program block to be imported from the global library to the "Program
blocks" folder.
4. Proceed as described in steps 2 and 3 for the other blocks.
Result
The program blocks are inserted in the project folder of the same name.d phase offset can be changed
Main [OB35] is located below the program blocks inserted into the project. Main [OB35] is a
cyclic interrupt organization block (cyclic interrupt OB). Cyclic interrupt OBs serve to start
In the following section, you will change the cycle time for the "Main" program block.
Requirement
● The program block "Main" [OB35] is contained in the library
● The FB/FC calls exist
Procedure
1. Open the properties of the "Main" program block.
2. Select the "Cyclic interrupt" option under "General".
3. Enter the new value for the "Cycle time" and click "OK".1. Open the "PLC tags" folder in the project navigation.
2. Open the "PLC_tags" folder.
3. Drag-and-drop the tag table to be imported from the global library to the "PLC tags"
folder.
4. Proceed as described in step 3 for the other tag tables.
Result
The tag tables are inserted in the project folder of the same name.. Select the "Color_Mixing_CPU" CPU in the project tree.
2. Right-click to open the shortcut menu and then select "Compile" > "Hardware and