Place of Origin: | GERMANY |
Brand Name: | LENZE |
Certification: | CE |
Model Number: | E82ZAFSC001 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
LENZE: | LENZE | E82ZAFSC001: | E82ZAFSC001 |
---|---|---|---|
GERMANY: | GERMANY | Material: | Iron |
Color: | Black | Temperature: | 20-90 |
Wire: | Wire | Dimension: | 80mm |
In the "Password" column, specify a password for the selected access level. In the | You must enter a password in the first row ("Full access" access level). |
Confirmation" column, enter the selected password again to protect against incorrect entries. |
|
Ensure that the password is sufficiently secure, in other words, that is does not follow a pattern that can be recognized by a machine! |
This enables
unrestricted access to the CPU for those who know the password, regardless of the
selected protection level.
5. Assign additional passwords as needed to other access levels if the selected access level
allows you to do so.
6. Download the hardware configuration to the CPU, so that the access level will take effect.
Behavior of a password-protected CPU during operation
The CPU protection takes effect after the settings are downloaded in the CPU.
Before an online function is executed, the necessary permission is checked and, if
necessary, the user is prompted to enter a password. The functions protected by a password
can only be executed by one programming device/PC at any one time. Another programming
device/PC cannot log on.
Access authorization to the protected data is in effect for the duration of the online
connection, or until the access authorization is manually rescinded with "Online > Delete
access rights".
Access to a password-protected CPU in the RUN mode can be limited locally in the display
so that access with a password is also not possible.If the protection level "Complete protection" was set for the CPU, the HMI device can only
access the CPU with the password stored there.
This function is only available with HMI devices from .
Procedure
1. Open the "Connections" editor in the project tree.
2. Select the integrated connection.
3. Enter the password for the CPU in the "Password" area.
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of
identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of products
Note the following:
WARNING
products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by . Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editionsRedundant automation systems are used in practice to achieve greater availability. In
redundantly operated systems, failure or malfunction of individual automation components
must not impede the operation of the plant.
R/H redundant system
For the R/H redundant system, the CPUs are duplicated, in other words redundant.
The two CPUs process the same project data and the same user program in parallel.