Place of Origin: | GERMANY |
Brand Name: | LENZE |
Certification: | CE |
Model Number: | E84AV-BDE1124SX0 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
LENZE: | LENZE | E84AV-BDE1124SX0: | E84AV-BDE1124SX0 |
---|---|---|---|
Material: | Iron | Gerany: | Germany |
Color: | Black | Temperature: | 20-90 |
Wire: | Wire |
2 fiber-optic cables, PROFINET cables
PC/PG with EngineeringSystem
2 fiber-optic cables, PROFINET cables PC/PG with EngineeringSystem |
programming of the user program. |
PG/PC with Ethernet interface and the following correctly installed software package: • SIMATIC STEP 7 Professional, V15.1 or later Switch for the connection of |
You can find additional information on installation and wiring of an ET 200SP in the ET 200SP distributed I/O system The wiring diagram for an ET 200SP for a tunnel section can be found in the section Wiring |
the PG/PC SCALANCE X-204IRYou can set up and wire the hardware before or after configuration and |
diagram for a tunnel section (Page 13). The procedure for installation and wiring of an R/H redundant system is available in the R/H redundant system Steps and settings which are specific for configuration and |
programming of an H
redundant system will be dealt with in detail in the following sections. Procedures which you
are already familiar with from configuring and programming a SIMATIC will only be
briefly outlined.
1.5 Wiring diagram for a tunnel section
Introduction
The figures below show the wiring of the I/O modules of an ET 200SP distributed I/O system
for tunnel section 1 or 3.
When wiring the tunnel section 2, there is no wiring of the digital output modules for the
traffic lights control and barrier control nor of the outdoor light sensor on the analog input
module.Interface module IM 155-6 PN HF (6ES7155-6AU01-0CN0 firmware version V4.2 and later)
② Traffic light control: DQ 4x24VDC/2A ST digital output module with a light-colored BaseUnit BU15-P16+A0+2D (BU
type A0)
③ Barrier control: DQ 4x24VDC/2A ST digital output module with a dark-colored BaseUnit BU15-P16+A0+2B (BU
type A0)
④ Measuring the light intensity and air pollution level: 4xU/I 2-wire ST analog input module with a dark-colored BaseUnit
BU15-P16+A0+2B (BU type A0)
⑤ Fan control system: DQ 4x24VDC/2A ST digital output module with a light-colored BaseUnit BU15-P16+A0+2D
(BU type A0)
⑥ Light control system: DQ 4x24..230VAC/2A HF digital output module with a light-colored BaseUnit BU20-
P16+A0+2D (BU type U0)
⑦ Server module
⑧ Mounting rail grounded at PE
⑨ Load current supply with 24 V DC output voltage (with safe electrical isolation)
⑩ PROFINET cables for the PROFINET ring
Figure 1-3 Wiring diagramThe following figure shows the wiring of the barrier control on the DQ 4x24VDC/2A ST digital
output module ③.
The barrier is opened and closed via a three-phase motor. The direction of rotation of the
three-phase motor is controlled via a reversing contactor:
● Open barrier → Contactor K1 actuated
● Close barrier → Contactor K2 actuated
If the barriers have reached their respective end position, they automatically switch off via
limit switches.The following figure shows the wiring of the sensors for measuring the light intensity and air
pollution level on the AI 4xU/I 2-wire ST analog input moduleThe following figure shows the wiring of the fan control on the DQ 4x24VDC/2A ST digital
output module ⑤.
The direction of rotation of the fan (right/left) is controlled via a reversing contactor:
● Fan rotates clockwise → Contactor K1 actuated
● Fan rotates counterclockwise → Contactor K2 actuated
The speed (high/low) of the fan is controlled via a Dahlander circuit: