Place of Origin: | GERMANY |
Brand Name: | LENZE |
Certification: | CE |
Model Number: | E82EV402K2C |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
LENZE: | LENZE | E82EV402K2C: | E82EV402K2C |
---|---|---|---|
GERMANY: | GERMANY | Material: | Iron |
Color: | Black | Temperature: | 20-90 |
Wire: | Wire | Dimension: | 60mm |
f the R/H redundant system is exposed to severe shock or vibration, take appropriate measures to reduce the acceleration or the amplitude. |
vertical mounting position: 0 °C to 60 °C 0 °C to 40 °C To increase the service life of the display, the display switches off when the permitted operating |
f the R/H redundant system is exposed to severe shock or vibration, take appropriate measures to reduce the acceleration or the amplitude. |
temperature is exceeded. At certain temperatures, the display switches off an on again. You can find more information in the technical specifications in the CPU manuals. |
onditions for the R/H redundant system: Table 13- 8 Climatic ambient conditions Ambient conditions Permissible Temperature: horizontal mounting position: |
Temperature variation 10 K/h - Relative humidity from 10 % to 95 % Without condensation Barometric pressure From 1140 to 795 hPa corresponds to an altitude of -1000 m to 2000 m Pollutant concentration ANSI/ISA-71.04 severity level G1; G2; The insulation is designed in accordance with the requirements of IEC 61010-2-201. |
Note
For modules with 24 V DC (SELV/PELV) supply voltage, electrical isolation is tested with
707 V DC (type test).
Pollution degree/overvoltage category in accordance with IEC 61131-2, IEC 61010-2-201
● Pollution degree 2
● Overvoltage category: II
Protection class according to IEC 61131-2, IEC 61010-2-201
The R/H redundant system meets protection class I requirements and parts of
protection classes II and III.Degree of protection IP20 in accordance with IEC 60529 for all modules of the R/H
redundant system:
● Protection against contact with standard test fingers
● Protection against foreign objects with diameters in excess of 12.5 mm
● No protection against water
Rated voltage for operation
The R/H redundant system works with the rated voltages and corresponding
tolerances listed in the table below.
Table 13- 9 Rated voltage for operation
rated voltage Tolerance range
24 V DC 19.2 V DC to 28.8 V DC1)
1) Static value: Generation as functional extra-low voltage with safe electrical isolation in accordance
with IEC 61131-2 or IEC 61010-2-201You can find more information in the product information Use of modules in a Zone 2
Hazardous Area (You can find more article numbers for the R/H redundant system on the Programmable logic controller for the open-loop and closed-loop control of process chains in
the process engineering industry and in manufacturing technology. The automation system
consists of different components and integrated system functions according to the
automation task.
Backup CPU
Role of a CPU in the R/H redundant system. If the R/H system is in the RUNRedundant
system state, the primary CPU controls the process. The backup CPU processes
the user program synchronously and can take over process control if the primary CPU fails.
Baud rate
Data transmission rate indicates the number of bits transmitted per second (baud rate = bit
rate).
Bit memory
Bit memory is a component of the system memory of the CPU for saving intermediate
results. You access the bit memory through the user program bit by bit, byte by byte, word
by word or double word by double word.
Bus
Joint transmission path to which all devices in a fieldbus system are connected.
Bus cable connector
The bus cable connector is the physical connection between bus node and bus cable.
Bus, self-assembling
The modules are lined up on the mounting rail. They are mechanically and electrically
connected to each other with a U connector as they are swiveled into position. In this way
the bus is extended with each module.In SIMATIC S7, a code block contains part of the STEP 7 user program.
Configuration
Systematic arrangement of the individual modules (configuration).
Connection plug
The connection plug provides the physical connection between devices and the cable, for
example.
Consistent data
Consistent data is data that belongs together in terms of content. Consistent data items are
read and written together.