The program block calculates how long each of the four valves needs to stay open for the color mixture | block calculates the quantity remaining in the tank for the tank fill level. The fill levels of the tanks are stored in th |
ased on the specified recipe and the number of tins that have to be filled. ③ LEDs below the tanks indicate that the valves are opened. |
The fill level indicators in the HMI screen are directly linked with the global data block and are updated |
④ The "LAD_Tanks_Filling_Level" program block is executed at the same time as the filling. The program | with each runtime acquisition cycle.The "Start mixing process" button starts the mixer of the color mixing plant in the HMI |
screen "Start screen".
② The "LAD_Mixer" program block is called for this purpose at the CPU end. It activates
the mixer for three seconds.
③ The activation of the mixer is indicated by flashing in the HMI screen.The "Fill Color Mixture" button starts the filling of the tins in the HMI screen "Start
screen".
② The "SCL_Valve_Conveyor" program block is activated for this purpose at the CPU
end; it controls the valves and the conveyor belt.
③ The tins are animated according to the movement of the conveyor belt in the HMI
screen.
④ A counter indicates the number of tins that have already been filled.There is a button to reset the fill level of each of the four color tanks in the HMI screen
"Start screen".
② The reset of the respective fill level has been implemented in the "Main" program
block in networks 6 to 9.
③ Networks 6 to 9 reset the values to the Start value in the global data block "Filling".The new SIMATIC controller family with the Totally Integrated Automation Portal
(TIA Portal) offers you numerous new options to further increase the productivity of your
machines and to make the engineering process even more efficient. Explore the options in
this Getting Started.
In the first basic steps, you will get to know the new hardware better. We will also show you
how to configure and program the SIMATIC with SIMATIC STEP 7 V13
(TIA Portal). The connection of a SIMATIC HMI Comfort Panel with SIMATIC WinCC
Advanced V13 (TIA Portal) or SIMATIC WinCC Professional V13 (TIA Portal) completes the
basic steps.To implement the hardware section of this Getting Started, you will need:
● 1 × CPU 1511-1 PN (6ES7511-1AK00-0AB0)
● 1 × load current supply PM 70W 120/230VAC (6EP1332-4BA00)
● 1 × Mounting rail (6ES7590-1AB60-0AA0)
● 1 × digital input module DI 16x24VDC SRC BA (6ES7521-1BH50-0AA0)
● 1 × digital output module DQ 16x24VDC/0.5A ST (6ES7522-1BH00-0AB0)
● 2 × Front connectors (6ES7592-1AM00-0XB0)
● 1 × SIMATIC Memory Card with at 4 MB (e.g. 6ES7954-8LBxx-0AA0)
● 1 × Ethernet cable
The hardware mentioned above is also part of the following starter package: