Place of Origin: | GERMANY |
Brand Name: | HAROWE |
Certification: | CE |
Model Number: | 11BRW-300-F1/3 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | Western Union, MoneyGram, T/T |
Supply Ability: | 100pcs/week |
HAROWE: | HAROWE | 11BRW-300-F1/3: | 11BRW-300-F1/3 |
---|---|---|---|
Material: | Iron | Temperature: | 20-90 |
Color: | Black | Dimension: | 90mm |
Germany: | Germany |
You can use the SIMATIC Automation Tool to run commissioning and maintenance activities simultaneously on various SIMATIC stations as a bulk operation independently of the TIA |
|
he SIMATIC Automation Tool provides a multitude of functions: ● Scanning of a PROFINET/Ethernet network and identification of all connected CPUs |
|
Address assignment (IP, subnet, gateway) and station name (PROFINET device) to a CPU |
Transfer of the date and the programming device/PC time converted to UTC time to the
module
● Program download to CPU
● Operating mode switchover RUN/STOP
● Localization of the CPU by means of LED flashing
● Reading out CPU error information
● Reading the CPU diagnostic buffer
● Reset to factory settings
● Updating the firmware of the CPU and connected modules
You can find the SIMATIC Automation Tool on the InternetWith PRONETA (PROFINET network analysis), you analyze the PROFINET
network during commissioning. PRONETA features two core functions:
● The topology overview independently scans PROFINET and all connected components.
● The IO check is a fast test of the wiring and the module configuration of a system.
You can find PRONETA on the Internet Firmware update V1.0.0 or higher X --- / X
Identification data I&M0 to I&M3 V1.0.0 or higher X X
Parameter assignment in RUN V1.0.0 or higher X X
Module internal shared input (MSI) V1.0.0 or higher X
(PROFINET IO only)
X
(PROFINET IO only)
Configurable submodules / submodules
for Shared Device
V1.0.0 or higher X
(PROFINET IO only)
X
(PROFINET IO only)
You can configure the module with STEP 7 (TIA Portal) and with a GSD file.
Accessories
The following accessories are supplied with the module and can also be ordered separately
as spare parts:
● Labeling strips
● U connector
● Universal front cover
Other components
The following component must be ordered separately:
Front connectors, including potential jumpers and cable ties
You can find additional information on accessories in the system manual /ET 200MPThis section contains the block diagram of the module and outlines various wiring options.
You can find information on wiring the front connector, establishing a cable shield, etc. in the
system manual /ET 200MPDo not insert the potential jumpers included with the front connector!
Wiring and block diagram
The figure below shows you how to wire the mTo detect a wire break, it is necessary that enough quiescent current is flowing even when
the encoder contacts are open. Connect a resistor to the encoder contacts for this reason,
see figure below.When you assign the module parameters in STEP 7, you use various parameters to specify
the module properties. The following table lists the configurable parameters. The effective
range of the configurable parameters depends on the type of configuration. The following
configurations are possible:
● Central operation with a CPU
● Distributed operation on PROFINET IO in an ET 200MP system
● Distributed operation on PROFIBUS DP in an ET 200MP system
For parameter assignment in the user program, the parameters are transferred to the
module using the WRREC instruction (parameter assignment in RUN) and data records; see
chapter Parameter assignment and structure of the parameter data records (Page 32)f you are operating channels of the module with an AC input voltage, you must set the input
delay for these channels at 20 ms.
If you set a different input delay, the input signal might be incorrectly altered and the wrong
value read.Enabling diagnostics if the line to the encoder is interrupted.
Input delay
This parameter can be used to suppress signal disruptions. Changes to the signal are only
detected if they are constantly pending longer than the set input delay time.
Hardware interrupt
Specifies whether or not a hardware interrupt is disabled or with which of the following
events a hardware interrupt is generated.
● Rising edge
● Falling edge
● Rising and falling edgeYou can configure the module with STEP 7 (TIA Portal) or with a GSD file.
When you configure the module by means of the GSD file, the configurations are available
under different abbreviations/module names.
The following configurations are possible:1 x 16-channel without value status
DI 16x24...125VUC HF X X
1 x 16-channel with value status DI 16x24...125VUC HF QI X X
2 x 8-channel without value status DI 16x24...125VUC HF S X
(PROFINET IO only)