    Product Details:

    Place of Origin: GERMANY
    Brand Name: HAROWE
    Certification: CE
    Model Number: 15BRCX-600-G4

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Packaging Details: carton
    Delivery Time: in stock
    Payment Terms: T/T, Western Union, MoneyGram
    Supply Ability: 100pcs/week
    Contact Now
    Detailed Product Description
    HAROWE: HAROWE Material: Iron
    Germany: Germany Color: Black
    Temperature: 20-90 Wire: Wire
    Dimension: 90mm

    HAROWE 15BRCX-600-G4 15BRCX-600-G4 15BRCX-600-G4 15BRCX-600-G4 15BRCX-600-G4HAROWE 15BRCX-600-G4 15BRCX-600-G4 15BRCX-600-G4 15BRCX-600-G4 15BRCX-600-G4HAROWE 15BRCX-600-G4 15BRCX-600-G4 15BRCX-600-G4 15BRCX-600-G4 15BRCX-600-G4HAROWE 15BRCX-600-G4 15BRCX-600-G4 15BRCX-600-G4 15BRCX-600-G4 15BRCX-600-G4

    Distributed operation on PROFIBUS DP in an ET 200MP system
    When assigning parameters in the user program, use the WRREC instruction to transfer the
     
    parameters to the module by means of data records; refer to the section Parameter
    assignment and structure of the parameter data records (Page 54).
     
    The following parameter settings for the channels are possible:Measuring range ±10 V Yes Channel Channel  

    Temperature coefficient Pt: 0.003851
    Pt: 0.003902
    Pt: 0.003916
    Pt: 0.003920
    Ni: 0.00618
    Ni: 0.00672
    LG-Ni: 0.005000
    0.003851 Yes Channel Channel
    • Temperature unit • Kelvin (K)
    • Fahrenheit (°F)
    • Celsius (°C)
    °C Yes Channel Module
    • Interference frequency
    suppression
    400 Hz
    60 Hz
    50 Hz
    10 Hz
    50 Hz Yes Channel Module
    • Smoothing None/low/medium/hi
    gh
    None Yes Channel Channel
    • Reference junction for TC • Fixed reference
    temperature
    • Dynamic reference
    temperature

    • Internal reference
    junction
    • Reference channel
    of the module
    Internal
    reference
    junction
    Yes Channel Module 5)
    • Dynamic reference
    temperature
    • Internal reference
    junction
    • Fixed reference temperature

    Temperature 25 °C Yes Channel --- 5)are deactivated, the module reports overflow or underflow (7FFFh or 8000h) in case of a wiring error. The alarm depends
    on whether the connected cables are faulty.
    Recommendation: Activate the "Wire break" diagnostics. The active check for wire break reliably detects wiring errors and
    the module reports overflow (7FFFH).
    2) When "Wire break" diagnostics is disabled, the current limit of 1.185 mA applies to the value status. For measured
    values below 1.185 mA, the value status is always: 0 = fault.
    3) If you enable diagnostics for multiple channels, you will receive an alarm surge on failure of the supply voltage because
    each enabled channel will detect this fault.
    You can prevent this message burst by assigning the diagnostics function to one channel only.
    4) You can set the effective range of the diagnostics for each channel in the user program with data records 0 to 7.
    5) You can set the current limit for wire break diagnostics, the setting "Fixed reference temperature" and "Reference channel
    of the module" as well as the limits for hardware interrupts in the user program with data records 0 to 7.
    Parameters of the reference channel

     

    You cannot configure the reference channel with GSD file. You have to transfer the
    reference channel to the module with data record 8.
    If you want to change the default settings, you have to transfer the parameters to the module
    with data record 8, see chapter Parameter assignment and structure of the parameter data
    records (Page 54).
    The diagnostics "Common mode error" and "Reference channel error" cannot be configured
    for the reference channel.Enabling of the diagnostics, with missing or too little supply voltage L+.
    Overflow
    Enabling of the diagnostics if the measured value violates the high limit.
    Underflow
    Enabling of the diagnostics when the measured value violates the low limit.
    Common mode error
    Enabling of diagnostics if the valid common mode voltage is exceeded.
    Enable the Common mode error diagnostics when 2WMT is connected, for example, to
    check for a short circuit to MANA or a wire break. If you do not need the Common mode error
    diagnostics, disable the parameter.
    Reference channel error
    ● Enable diagnostics for an error at the temperature compensation channel, e.g. wire
    break.
    ● Dynamic reference temperature compensation type is configured and no reference
    temperature has been transferred to the module yet.
    Wire break
    Enabling of the diagnostics if the module has no current flow or the current is too weak for
    the measurement at the corresponding configured input or the applied voltage is too low.
    Current limit for wire break diagnostics
    Threshold for reporting wire breaks. The value can be set to 1.185 mA or 3.6 mA, depending
    on the sensor used.
    Temperature coefficient

     