HAROWE: | HAROWE | 15BRCX-602-B10A/10: | 15BRCX-602-B10A/10 |
---|---|---|---|
GERMANY: | GERMANY | Material: | Iron |
Temperature: | 20-90 | Dimension: | 90mm |
Wire: | Wire | Color: | Black |
compensation of the cable resistances ? for resistance measurement with four-wire |
|
connection Yes; All measuring ranges except PTCLinearity error (relative to input range), (+/-) 0.02 % |
|
Temperature error (relative to input range), (+/- ) |
0.005 %/K; With TC type T 0.02 ± % / K
Crosstalk between the inputs, max. -80 dB
Repeat accuracy in steady state at 25 °C (relative
to input range), (+/-)
0.02 %
Temperature error of internal compensation ±6 °C
Operational error limit in overall temperature
range
? Voltage, relative to input range, (+/-) 0.3 %
? Current, relative to input range, (+/-) 0.3 %
? Resistance, relative to input range, (+/-) 0.3 %
? Resistance thermometer, relative to input
range, (+/-)
Ptxxx standard: ±1.5 K, Ptxxx climate: ±0.5 K,
Nixxx standard: ±0.5 K, Nixxx climate: ±0.3 K
? Thermocouple, relative to input range, (+/-) Type B: > 600 °C ±4.6 K, type E: > -200 °C ±1.5
K, type J: > -210 °C ±1.9 K, type K: > -200 °C
±2.4 K, type N: > -200 °C ±2.9 K, type R: > 0 °C
±4.7 K, type S: > 0 °C ±4.6 K, type T: > -200 °C
±2.4 K
Basic error limit (operational limit at 25 °C)
? Voltage, relative to input range, (+/-) 0.1 %
? Current, relative to input range, (+/-) 0.1 %
? Resistance, relative to input range, (+/-) 0.1 %
? Resistance thermometer, relative to input
range, (+/-)
Ptxxx standard: ±0.7 K, Ptxxx climate: ±0.2 K,
Nixxx standard: ±0.3 K, Nixxx climate: ±0.15 K
? Thermocouple, relative to input range, (+/-) Type B: > 600 °C ±1.7 K, type E: > -200 °C ±0.7
K, type J: > -210 °C ±0.8 K, type K: > -200 °C
±1.2 K, type N: > -200 °C ±1.2 K, type R: > 0 °C
±1.9 K, type S: > 0 °C ±1.9 K, type T: > -200 °C
±0.8 K
Interference voltage suppression for f = n x (f1 +/-
1 %), f1 = interference frequency
? Series mode interference (peak value of
interference < rated value of input range),
min.
40 dB
? Common mode voltage, max. 10 V
? Common mode interference, min. 60 dB
Isochronous mode
Isochronous operation (application synchronized
up to terminal)? Diagnostic alarm Yes
? Limit value alarm Yes; two upper and two lower limit values in each
case
Diagnostic messages
? Monitoring the supply voltage Yes
? Wire-break Yes; Only for 1 to 5 V, 4 to 20 mA, TC, R, and
RTD
? Overflow/underflow Yes
Diagnostics indication LED
? RUN LED Yes; Green LED
? ERROR LED Yes; Red LED
? Monitoring of the supply voltage (PWRLED)
Yes; Green LED
? Channel status display Yes; Green LED
? for channel diagnostics Yes; Red LED
? for module diagnostics Yes; Red LED
Potential separation
Potential separation channels
between the channels No
? between the channels, in groups of 8
? between the channels and backplane bus Yes
? between the channels and the power supply
of the electronics
Yes
Permissible potential difference
between the inputs (UCM) 20 V DC
Between the inputs and MANA (UCM) 10 V DC
Isolation
Isolation tested with 707 V DC (type test)
Standards, approvals, certificates
Suitable for applications according to AMS
2750
Yes; Declaration of Conformity, see online support
entry 109757262
Suitable for applications according to CQI-9 Yes; Based on AMS 2750 EAdditional basic error and noise for integration
time = 2.5 ms: Voltage: ±250 mV (±0.02%), ±80
mV (±0.05%), ±50 mV (±0.05%); resistance: 150
ohms ±0.02%; resistance thermometer: Pt100
climate: ±0.08 K, Ni100 climate: ±0.08 K; thermocouple:
Type B, R, S: ±3 K, type E, J, K, N, T: ±1
KThe dimensional drawing of the module on the mounting rail, as well as a dimensional
drawing with open front panel are provided in the appendix. Always adhere to the specified
dimensions for installations in cabinets, control rooms, etc.The data records of the module have an identical structure, regardless of whether you
configure the module with PROFIBUS DP or PROFINET IO.
Dependencies for configuration with GSD file