    Product Details:

    Place of Origin: GERMANY
    Brand Name: HAROWE
    Certification: CE
    Model Number: 15BRCX-602-B10A/10

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Packaging Details: carton
    Delivery Time: in stock
    Payment Terms: T/T, Western Union, MoneyGram
    Supply Ability: 100pcs/week
    Contact Now
    Detailed Product Description
    HAROWE: HAROWE 15BRCX-602-B10A/10: 15BRCX-602-B10A/10
    GERMANY: GERMANY Material: Iron
    Temperature: 20-90 Dimension: 90mm
    Wire: Wire Color: Black

    HAROWE 15BRCX-602-B10A/10 15BRCX-602-B10A/10 15BRCX-602-B10A/10 15BRCX-602-B10A/10HAROWE 15BRCX-602-B10A/10 15BRCX-602-B10A/10 15BRCX-602-B10A/10 15BRCX-602-B10A/10HAROWE 15BRCX-602-B10A/10 15BRCX-602-B10A/10 15BRCX-602-B10A/10 15BRCX-602-B10A/10HAROWE 15BRCX-602-B10A/10 15BRCX-602-B10A/10 15BRCX-602-B10A/10 15BRCX-602-B10A/10

    compensation of the cable resistances
    ? for resistance measurement with four-wire
     
    connection
    Yes; All measuring ranges except PTCLinearity error (relative to input range), (+/-) 0.02 %
     
    Temperature error (relative to input range), (+/-
    )
     

    0.005 %/K; With TC type T 0.02 ± % / K
    Crosstalk between the inputs, max. -80 dB
    Repeat accuracy in steady state at 25 °C (relative
    to input range), (+/-)
    0.02 %
    Temperature error of internal compensation ±6 °C
    Operational error limit in overall temperature
    range

    ? Voltage, relative to input range, (+/-) 0.3 %
    ? Current, relative to input range, (+/-) 0.3 %
    ? Resistance, relative to input range, (+/-) 0.3 %
    ? Resistance thermometer, relative to input
    range, (+/-)
    Ptxxx standard: ±1.5 K, Ptxxx climate: ±0.5 K,
    Nixxx standard: ±0.5 K, Nixxx climate: ±0.3 K
    ? Thermocouple, relative to input range, (+/-) Type B: > 600 °C ±4.6 K, type E: > -200 °C ±1.5
    K, type J: > -210 °C ±1.9 K, type K: > -200 °C
    ±2.4 K, type N: > -200 °C ±2.9 K, type R: > 0 °C
    ±4.7 K, type S: > 0 °C ±4.6 K, type T: > -200 °C
    ±2.4 K
    Basic error limit (operational limit at 25 °C)
    ? Voltage, relative to input range, (+/-) 0.1 %
    ? Current, relative to input range, (+/-) 0.1 %
    ? Resistance, relative to input range, (+/-) 0.1 %
    ? Resistance thermometer, relative to input
    range, (+/-)
    Ptxxx standard: ±0.7 K, Ptxxx climate: ±0.2 K,
    Nixxx standard: ±0.3 K, Nixxx climate: ±0.15 K
    ? Thermocouple, relative to input range, (+/-) Type B: > 600 °C ±1.7 K, type E: > -200 °C ±0.7
    K, type J: > -210 °C ±0.8 K, type K: > -200 °C
    ±1.2 K, type N: > -200 °C ±1.2 K, type R: > 0 °C
    ±1.9 K, type S: > 0 °C ±1.9 K, type T: > -200 °C
    ±0.8 K
    Interference voltage suppression for f = n x (f1 +/-
    1 %), f1 = interference frequency

    ? Series mode interference (peak value of
    interference < rated value of input range),
    min.
    40 dB
    ? Common mode voltage, max. 10 V
    ? Common mode interference, min. 60 dB
    Isochronous mode
    Isochronous operation (application synchronized
    up to terminal)? Diagnostic alarm Yes
    ? Limit value alarm Yes; two upper and two lower limit values in each
    case
    Diagnostic messages
    ? Monitoring the supply voltage Yes
    ? Wire-break Yes; Only for 1 to 5 V, 4 to 20 mA, TC, R, and
    RTD
    ? Overflow/underflow Yes
    Diagnostics indication LED
    ? RUN LED Yes; Green LED
    ? ERROR LED Yes; Red LED
    ? Monitoring of the supply voltage (PWRLED)
    Yes; Green LED
    ? Channel status display Yes; Green LED
    ? for channel diagnostics Yes; Red LED
    ? for module diagnostics Yes; Red LED
    Potential separation
    Potential separation channels

    between the channels No
    ? between the channels, in groups of 8
    ? between the channels and backplane bus Yes
    ? between the channels and the power supply
    of the electronics
    Yes
    Permissible potential difference
    between the inputs (UCM) 20 V DC
    Between the inputs and MANA (UCM) 10 V DC
    Isolation
    Isolation tested with 707 V DC (type test)
    Standards, approvals, certificates
    Suitable for applications according to AMS
    2750
    Yes; Declaration of Conformity, see online support
    entry 109757262
    Suitable for applications according to CQI-9 Yes; Based on AMS 2750 EAdditional basic error and noise for integration
    time = 2.5 ms: Voltage: ±250 mV (±0.02%), ±80
    mV (±0.05%), ±50 mV (±0.05%); resistance: 150
    ohms ±0.02%; resistance thermometer: Pt100
    climate: ±0.08 K, Ni100 climate: ±0.08 K; thermocouple:
    Type B, R, S: ±3 K, type E, J, K, N, T: ±1
    KThe dimensional drawing of the module on the mounting rail, as well as a dimensional
    drawing with open front panel are provided in the appendix. Always adhere to the specified
    dimensions for installations in cabinets, control rooms, etc.The data records of the module have an identical structure, regardless of whether you
    configure the module with PROFIBUS DP or PROFINET IO.
    Dependencies for configuration with GSD file