Home ProductsLeine linde

HAROWE 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B

HAROWE 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B

    • HAROWE 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B
    • HAROWE 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B
    • HAROWE 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B
    • HAROWE 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B
  • HAROWE 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B

    Product Details:

    Place of Origin: GERMANY
    Brand Name: HAROWE
    Certification: CE
    Model Number: 11BRCX-300-A-81B

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Packaging Details: carton
    Delivery Time: in stock
    Payment Terms: T/T, Western Union, MoneyGram
    Supply Ability: 100pcs/week
    Contact Now
    Detailed Product Description
    HAROWE: HAROWE 11BRCX-300-A-81B: 11BRCX-300-A-81B
    GERMANY: GERMANY Color: Black
    Temperature: 20-90 Material: Iron
    Dimension: 90mm

    HAROWE 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81BHAROWE 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81BHAROWE 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81BHAROWE 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B 11BRCX-300-A-81B

    Monitoring the supply voltage Yes
    • Wire-break Yes; only for 1 ... 5 V and 4 ... 20 mA
     
    Overflow/underflow YesRUN LED Yes; Green LED
    • ERROR LED Yes; Red LED
     
    Monitoring of the supply voltage (PWR-LED) Yes; Green LED
    • Channel status display Yes; Green LED
     

    for channel diagnostics Yes; Red LED
    • for module diagnostics Yes; Red LED
    Potential separation
    Potential separation channels
    • between the channels No
    • between the channels, in groups of 8
    • between the channels and backplane bus Yes
    • between the channels and the power supply of the electronics Yes
    Permissible potential difference
    between the inputs (UCM) 20 V DC
    Between the inputs and MANA (UCM) 10 V DC
    Isolation
    Isolation tested with 707 V DC (type test)
    Ambient conditions
    Ambient temperature during operation
    • horizontal installation, min. 0 °C
    • horizontal installation, max. 60 °C
    • vertical installation, min. 0 °C
    • vertical installation, max. 40 °C
    Decentralized operation
    Prioritized startup Yes
    Dimensions
    Width 35 mm
    Height 147 mm
    Depth 129 mm
    Weights
    Weight, approx. 300 gThis appendix contains the dimensional drawing of the module installed on a mounting rail
    and with a shield bracket. Always adhere to the specified dimensions for installations in
    cabinets, control rooms, etcThe data records of the module have an identical structure, regardless of whether you
    configure the module with PROFIBUS DP or PROFINET IO.
    Dependencies for configuration with GSD file
    When configuring the module with a GSD file, remember that the settings of some
    parameters are dependent on each other. The parameters are only checked for plausibility
    by the module after the transfer to the module.
    The following table lists the parameters that depend on one another.
    Table B- 1 Dependencies of parameters for configuration with GSD fileYou have the option to assign module parameters in RUN (e.g., the voltage or current values
    of selected channels can be edited in RUN without having an effect on the other channels).
    Parameter assignment in RUN
    The WRREC instruction is used to transfer the parameters to the module using data records
    0 to 7. The parameters set in STEP 7 do not change in the CPU, which means the
    parameters set in STEP 7 are still valid after a restart.
    The parameters are only checked for plausibility by the module after the transfer to the
    module.
    Output parameter STATUS
    The module ignores errors that occurred during the transfer of parameters with the WRREC
    instruction and continues operation with the previous parameter assignment. However, a
    corresponding error code is written to the STATUS output parameter.
    The description of the WRREC instruction and the error codes is available in the STEP 7
    online help.If the module is operated behind a PROFIBUS DP interface module, the parameter data
    records 0 and 1 are not read back. You obtain the diagnostics data records 0 and 1 with the
    read back parameter data records 0 and 1. You can find additional information in the
    Interrupts section of the manual for the PROFIBUS DP interface module on the For the configuration as a 1 x 8-channel module, the parameters are located in data records
    0 to 7 and are assigned as follows:
    ● Data record 0 for channel 0
    ● Data record 1 for channel 1
    ● …
    ● Data record 6 for channel 6
    ● Data record 7 for channel 7
    For configuration 8 x 1-channel, the module has 8 submodules with one channel each. The
    parameters for the channel are available in data record 0 and are assigned as follows:
    ● Data record 0 for channel 0 (submodule 1)
    ● Data record 0 for channel 1 (submodule 2)
    ● …
    ● Data record 0 for channel 6 (submodule 7)
    ● Data record 0 for channel 7 (submodule 8)
    Address the respective submodule for data record transfer.The figure below shows the structure of data record 0 for channel 0 as an example. The
    structure is identical for channels 1 to 7. The values in byte 0 and byte 1 are fixed and may
    not be changed.
    Enable a parameter by setting the corresponding bit to "1You can only configure the oversampling function with STEP 7 (TIA Portal) via the
    sampling rate parameter.The following table lists all measuring types of the analog input module along with their
    codes. Enter these codes at byte 2 of the respective data record (see previous figure).
    Table B- 2 Code for the measuring type
    Measurement type Code
    Deactivated 0000 0000
    Voltage 0000 0001
    Current 4-wire transmitter 0000 0010
    Current 2-wire transmitter 0000 0011
    Codes for measuring ranges
    The following table lists all measuring ranges of the analog input module along with their
    codes. Enter these codes at byte 3 of the respective data record (see previous figure).
    Table B- 3 Code for the measuring range
    Measuring range Code

    Contact Details
    Guang Zhou Lai Jie Electric Co.,Ltd

    Contact Person: Mr. Tommy

    Tel: 86-020-87268766

    Fax: 86-020-87269099

    Send your inquiry directly to us (0 / 3000)