Place of Origin: | GERMANY |
Brand Name: | HAROWE |
Certification: | CE |
Model Number: | 11BRCX-300-G10T/5 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
HAROWE: | HAROWE | 11BRCX-300-G10T/5: | 11BRCX-300-G10T/5 |
---|---|---|---|
Material: | Iron | Temperature: | 20-90 |
Color: | Black | Dimension: | 90mm |
Wire: | Wire |
vFast mode: 4 / 18 / 22 / 102 ms; standard mode: 9 / 52 / 62 / 302 ms |
|
Interference voltage suppression for interference frequency f1 in Hz 400 / 60 / 50 / 10 H |
|
Basic execution time of the module (all channels enabled) |
Corresponds to the channel with the highest
basic conversion timeFor voltage measurement Yes
for current measurement as 2-wire transducer Yes; with external transmitter supply
for current measurement as 4-wire transducer Yes
Errors/accuracies
Linearity error (in relation to input range), (+/-) 0.02%
Temperature error (in relation to input range), (+/-) 0.005%/K
Crosstalk between the inputs, max. -80 dB
Repeat accuracy in settled state at 25 °C (in relation
to input range), (+/-)
0.02%
Operational limit in overall temperature range
Voltage in relation to input range, (+/-) 0.1%
Current in relation to input range, (+/-) 0.1%
Basic error limit (operational limit at 25 °C)
Voltage in relation to input range, (+/-) 0.05%
Current in relation to input range, (+/-) 0.05%
Interference voltage suppression for f = n x (f1 +/-
1 %), f1 = interference frequency
Series-mode interference (peak of the interference
< rated value of the input range), min.
80 dB; in Standard mode, 40 dB in Fast mode
Common mode voltage, max. 60 V DC / 30 V AC
Common mode interference, min. 80 dB
Isochronous mode
Isochronous mode (application synchronized up to
terminal)
No
Interrupts/diagnostics/status information
Diagnostics function Yes
Interrupts
Diagnostic interrupt Yes
Limit interrupt Yes; two high limits and two low limits each
Diagnostics alarms
Monitoring of supply voltage Yes
Wire break Yes; only for 1 to 5 V and 4 to 20 mA
Overflow/underflow YesRUN LED Yes; green LED
ERROR LED Yes; red LED
Monitoring of supply voltage (PWR LED) Yes; green LED
Channel status display Yes; green LED
For channel diagnostics Yes; red LED
For module diagnostics Yes; red LED
Electrical isolation
Electrical isolation of channels
Between the channels Yes
Between the channels, in groups of 1
Between the channels and backplane bus Yes
Between the channels and power supply of the
electronics
Yes
Permitted potential difference
Between different circuits 60 V DC / 30 V AC; Isolation measured for 120 V
AC basic isolation: Between the channels and
supply voltage L+, between the channels and the
backplane bus, between the channels
Isolation
Isolation tested with 2000 V DC between the channels and the supply
voltage L+, 2000 V DC between the channels and
the backplane bus, 2000 V DC between the
channels, 707 V DC (type test) between the supply
voltage L+ and the backplane bus
Ambient conditions
Ambient temperature during operation
Horizontal mounting position, min. 0 °C
Horizontal mounting position, max. 60 °C
Vertical mounting position, min. 0 °C
Vertical mounting position, max. 40 °C
Distributed mode
Prioritized startup Yes
Dimensions
Width 35 mm
Height 147 mm
Depth 129 mm
Weights
Weight, approx. 280 gThis appendix contains the dimensional drawing of the module installed on a mounting rail