    Product Details:

    Place of Origin: GERMANY
    Brand Name: HAROWE
    Certification: CE
    Model Number: 11BRCX-300-C-58

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Packaging Details: carton
    Delivery Time: in stock
    Payment Terms: T/T, Western Union, MoneyGram
    Supply Ability: 100pcs/week
    Contact Now
    Detailed Product Description
    HAROWE: HAROWE 11BRCX-300-C-58: 11BRCX-300-C-58
    GERMANY: GERMANY Temperature: 20-90
    Color: Black Material: Iron
    Wire: Wire Dimension: 90mm

    HAROWE 11BRCX-300-C-58 11BRCX-300-C-58 11BRCX-300-C-58 11BRCX-300-C-58 11BRCX-300-C-58HAROWE 11BRCX-300-C-58 11BRCX-300-C-58 11BRCX-300-C-58 11BRCX-300-C-58 11BRCX-300-C-58HAROWE 11BRCX-300-C-58 11BRCX-300-C-58 11BRCX-300-C-58 11BRCX-300-C-58 11BRCX-300-C-58HAROWE 11BRCX-300-C-58 11BRCX-300-C-58 11BRCX-300-C-58 11BRCX-300-C-58 11BRCX-300-C-58

    Configurable YesConnection of the signal encoders
    For voltage measurement Yes
     
    for current measurement as 2-wire transducer Yes
    Load of 2-wire transmitter, max. 820 Ω
     
    or current measurement as 4-wire transducer Yes
    for resistance measurement with two-wire connection
     

    Yes; only for PTC
    for resistance measurement with three-wire connection
    Yes; all measuring ranges except PTC; internal
    compensation of line resistance
    for resistance measurement with four-wire connection
    Yes; all measuring ranges except PTCLinearity error (in relation to input range), (+/-) 0,02 %
    Temperature error (in relation to input range), (+/-) 0.005%/K; for TC typ. T 0.02 +/- %/K
    Crosstalk between the inputs, max. -80 dB
    Repeat accuracy in settled state at 25 °C (in relation
    to input range), (+/-)
    0.02 %
    Temperature errors of internal compensation +/-6 °C
    Operational limits across the entire temperature
    range
    Voltage in relation to input range, (+/-) 0.3 %
    Current in relation to input range, (+/-) 0.3 %
    Resistance in relation to input range, (+/-) 0.3 %
    Resistance thermometer in relation to input range,
    (+/-)
    0.3 %;
    Pt xxx Standard: ±1.5 K,
    Pt xxx Climate: ±0.5 K,
    Ni xxx Standard: ±0.5 K,
    Ni xxx Climate: ±0.3 K
    Thermocouple in relation to input range, (+/-) 0.3 %;
    Type B: >600°C +/- 4.6K
    Type E: >-200°C +/- 1.5K
    Type J: >-210°C +/- 1.9K
    Type K: >-200°C +/- 2.4K
    Type N: >-200°C +/- 2.9K
    Type R: >0°C +/- 4.7K
    Type S: >0°C +/- 4.6K
    Type T: >-200°C +/- 2.4 K
    Basic error limit (operational limit at 25 °C)
    Voltage in relation to input range, (+/-) 0,1 %
    Current in relation to input range, (+/-) 0,1 %
    Resistance in relation to input range, (+/-) 0,1 %
    Resistance thermometer in relation to input range,
    (+/-)
    0.1 %;
    Pt xxx Standard: ±0.7 K,
    Pt xxx Climate: ±0.2 K,
    Ni xxx Standard: ±0.3 K,
    Ni xxx Climate: ±0.15 K
    Thermocouple in relation to input range, (+/-) 0.1 %;
    Type B: >600°C +/- 1.7K
    Type E: >-200°C +/- 0.7K
    Type J: >-210°C +/- 0.8K
    Type K: >-200°C +/- 1.2K
    Type N: >-200°C +/- 1.2K
    Type R: >0°C +/- 1.9K
    Type S: >0°C +/- 1.9K
    Type T: >-200°C +/- 0.8K1 %), f1 = interference frequency
    Series mode interference (peak value of interference
    < rated value of input range), min.
    40 dB
    Common mode voltage, max. 10 V
    Common mode interference, min. 60 dB
    Interrupts/diagnostics/status information
    Interrupts
    Diagnostics interrupt Yes
    Limit interrupt Yes; two high limits and two low limits each
    Diagnostics alarms
    Diagnostics Yes
    Monitoring of supply voltage Yes
    Wire break Yes, only for 1 ... 5V, 4 ... 20mA, TC, R and RTD
    Overflow/underflow Yes
    Diagnostics display LED
    RUN LED Yes; green LED
    ERROR LED Yes; red LED
    Monitoring of supply voltage Yes; green LED

     

    Channel status display Yes; green LED
    For channel diagnostics Yes; red LED
    For module diagnostics Yes; red LED
    Electrical isolation
    Electrical isolation channels
    Between the channels No
    Between the channels, in groups of 4
    Between the channels and the backplane bus Yes
    Between the channels and the supply voltage of
    the electronics
    Yes
    Permissible potential difference
    Between the inputs (UCM) 20 V DC
    Between inputs and MANA (UCM) 10 V DC
    Between M internally and the inputs 75 V DC / 60 V AC (basic isolation)
    Isolation
    Isolation tested with 707 V DC (type test)
    Distributed mode
    Prioritized startup NoPackage includes 40-pin push-in front connector
    Additional basic error and noise for integration
    time = 2.5 ms: Voltage: +/- 250 mV:
    +/- 0.02% +/- 80mV: +/- 0.05% +/- 50 mV: +/-
    0.05% resistance: 150 ohm: +/- 0.02% resistance
    thermometer: Pt100 climate: +/- 0.08 K
    Ni100 Climate: +/-0.08K thermocouple: Type B,
    R, S:
    +/- 3K Type E, J, K, N, T: +/-1 KThe dimension drawing of the module on the mounting rail, as well as a dimension drawing
    with open front panel are provided in the appendix. Always adhere to the specified
    dimensions for installation in cabinets, control rooms, etcDimension drawing of the AI 4xU/I/RTD/TC ST module, side view with open front panelThe data records of the module have an identical structure, regardless of whether you
    configure the module with PROFIBUS DP or PROFINET IO.
    Dependencies for configuration with GSD file
    When configuring the module with a GSD file, remember that the settings of some
    parameters are dependent on each other. The parameters are only checked for plausibility
    by the module after the transfer to the module.
    The following table lists the parameters that depend on one another.
    Table B- 1 Dependencies of parameters for configuration with GSD fileOnly for measurement type resistance, thermistor RTD, thermocouple
    TC, voltage with measuring range 1V to 5 V and current with measuring
    range 4 to 20 mA.
    Common mode error Only for measuring type voltage, current and thermocouple TC.
    Reference junction Only for measurement type thermocouple TC.