Home ProductsLeine linde

LENZE EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100

LENZE EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100

    • LENZE EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100
    • LENZE EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100
    • LENZE EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100
    • LENZE EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100
  • LENZE EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100

    Product Details:

    Place of Origin: GERMANY
    Brand Name: LENZE
    Certification: CE
    Model Number: EVS9332-EKK100

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Packaging Details: carton
    Delivery Time: in stock
    Payment Terms: T/T, Western Union, MoneyGram
    Supply Ability: 100pcs/week
    Contact Now
    Detailed Product Description
    LENZE: LENZE EVS9332-EKK100: EVS9332-EKK100
    Material: Iron Color: Black
    Temperature: 20-90 Dimension: 90mm
    Wire: Wire Germany: Germany

    LENZE EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100LENZE EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100LENZE EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100LENZE EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100 EVS9332-EKK100

    You can use the SIMATIC Automation Tool to run commissioning and maintenance activities
    simultaneously on various SIMATIC S7 stations as a bulk operation independently of the TIA
    Portal.
     
    The SIMATIC Automation Tool provides a multitude of functions:
    ● Scanning of a PROFINET/Ethernet network and identification of all connected CPUs
     
    Address assignment (IP, subnet, gateway) and station name (PROFINET device) to a
    CPU
     

    ransfer of the date and the programming device/PC time converted to UTC time to the
    module
    ● Program download to CPU
    ● Operating mode switchover RUN/STOP
    ● Localization of the CPU by means of LED flashing
    ● Reading out CPU error information
    ● Reading the CPU diagnostic buffer
    ● Reset to factory settings
    ● Updating the firmware of the CPU and connected modules
    You can find the SIMATIC Automation Tool on the With PRONETA (PROFINET network analysis), you analyze the PROFINET
    network during commissioning. PRONETA features two core functions:
    ● The topology overview independently scans PROFINET and all connected components.
    ● The IO check is a fast test of the wiring and the module configuration of a system.
    You can find PRONETA on the he module has the following technical properties:
    ● 16 digital inputs; electrically isolated in groups of 1
    ● Rated input voltage 24 V UC to 125 V UC
    ● Configurable diagnostics (per channel)
    ● Configurable hardware interrupt (per channel)
    ● Programmable input delay (only with DC)
    ● Suitable for switches and 2-/3-/4-wire proximity switchesFirmware update V1.0.0 or higher X --- / X
    Identification data I&M0 to I&M3 V1.0.0 or higher X X
    Parameter assignment in RUN V1.0.0 or higher X X
    Module internal shared input (MSI) V1.0.0 or higher X
    (PROFINET IO only)
    X
    (PROFINET IO only)
    Configurable submodules / submodules
    for Shared Device
    V1.0.0 or higher X
    (PROFINET IO only)
    X
    (PROFINET IO only)
    You can configure the module with STEP 7 (TIA Portal) and with a GSD file.
    Accessories
    The following accessories are supplied with the module and can also be ordered separately
    as spare parts:
    ● Labeling strips
    ● U connector
    ● Universal front cover
    Other components
    The following component must be ordered separately:
    Front connectors, including potential jumpers and cable ties
    You can find additional information on accessories in the system manual /ET 200MP This section contains the block diagram of the module and outlines various wiring options.
    You can find information on wiring the front connector, establishing a cable shield, etc. in the
    system manual /ET 200MP To detect a wire break, it is necessary that enough quiescent current is flowing even when
    the encoder contacts are open. Connect a resistor to the encoder contacts for this reason,
    see figure below.
    Rated input voltage: Resistance:
    24 VUC 16 kΩ ... 21 kΩ with 1.0 W
    48 VUC 37 kΩ ... 53 kΩ with 0.5 W
    125 VUC 101 kΩ ... 156 kΩ with 0.25 W
    Figure 3-2 Resistor circuitry of the encoders If you are operating channels of the module with an AC input voltage, you must set the input
    delay for these channels at 20 ms.
    If you set a different input delay, the input signal might be incorrectly altered and the wrong
    value read.
    4.2 Declaration of parameters
    Wire break
    Enabling diagnostics if the line to the encoder is interrupted.
    Input delay
    This parameter can be used to suppress signal disruptions. Changes to the signal are only
    detected if they are constantly pending longer than the set input delay time.
    Hardware interrupt
    Specifies whether or not a hardware interrupt is disabled or with which of the following
    events a hardware interrupt is generated.
    ● Rising edge
    ● Falling edge
    ● Rising and falling edgeThe module can be configured differently in STEP 7; see following table. Depending on the
    configuration, additional/different addresses are assigned in the process image of the inputs.
    The letters "a" and "b" are printed on the module. "IB a" for example, stands for module start

    Contact Details
    Guang Zhou Lai Jie Electric Co.,Ltd

    Contact Person: Mr. Tommy

    Tel: 86-020-87268766

    Fax: 86-020-87269099

    Send your inquiry directly to us (0 / 3000)