Sales & Support : Request A Quote
English
Home ProductsLeine linde

LENZE EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100

LENZE EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100

    • LENZE EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100
    • LENZE EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100
    • LENZE EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100
    • LENZE EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100
  • LENZE EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100

    Product Details:

    Place of Origin: GERMANY
    Brand Name: LENZE
    Certification: CE
    Model Number: EVS9332-ERV100

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Packaging Details: carton
    Delivery Time: in stock
    Payment Terms: T/T, Western Union, MoneyGram
    Supply Ability: 100pcs/week
    Contact Now
    Detailed Product Description
    LENZE: LENZE GERMANY: GERMANY
    Material: Iron Color: Black
    Temperature: 20-90 Dimension: 90mm
    EVS9332-ERV100: EVS9332-ERV100

    LENZE EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100LENZE EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100LENZE EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100LENZE EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100 EVS9332-ERV100

    The number of IO controllers depends on the interface module used. Observe the  
    information in the manual for the particular interface module.The meaning of the value status depends on the submodule on which it occurs.  
    For the first submodule (=basic submodule), the value status 0 indicates that the value is
    incorrect or that the IO controller of the basic submodule is in STOP state.
     

    For 2nd to 4th submodule (=MSO submodule), the value status 0 indicates that the value is
    incorrect or one of the following errors has occurred:
    ● The basic submodule is not yet configured (not ready).
    ● The connection between the IO controller and the basic submodule has been interrupted.
    ● The IO controller of the basic submodule is in STOP or POWER OFF state.
    The following figure shows the assignment of the address space for submodules 1 and 2 and
    the value status.You can find information on the Shared Input/Output (MSI/MSO) function in the section
    Module-Internal Shared Input/Output (MSI/MSO) of the PROFINET with STEP 7 V13The tables below explain the meaning of the status and error displays. Remedial measures
    for diagnostic alarms can be found in section Diagnostic alarms (Page 28).
    RUN and ERROR LED
    Table 5- 1 Status and error displays RUN and ERROR
    LED Meaning Solution
    RUN ERROR
    Off Off
    Voltage missing or too low at backplane bus • Switch on the CPU and/or the system power
    supply modules.
    • Verify that the U connectors are inserted.
    • Check to see if too many modules are inserted.
    Flashes Off
    The module starts and flashes until the valid
    parameter assignment is set.
    ---
    On Off
    Module is configured
    On Flashes
    Indicates module errors (at least one error at
    one channel, e.g., short-circuit to ground).
    Evaluate the diagnostics data and eliminate the
    error (e.g., check the cables).
    Flashes Flashes
    Hardware defective Replace the module.
    LED MAINT
    Table 5- 2 MAINT status display
    LED MAINT Meaning Solution

    Off
    0 = No maintenance interrupt is pending. ---

    On
    1 = The maintenance interrupt "Limit value
    warning" is pending.The data records of the module have an identical structure, regardless of whether you
    configure the module with PROFIBUS DP or PROFINET IO.
    Dependencies for configuration with GSD file
    When a GSD file is used to configure a module, dependencies can arise when "assigning the
    parameters".
    There are no dependencies for this module. You can assign the individual parameters in any
    combinationYou have the option to reconfigure the modules in RUN (e.g. the response of selected
    channels to the CPU-STOP state can be changed in RUN without having an effect on the
    other channels)
    Parameter assignment in RUN
    The WRREC instruction is used to transfer the parameters to the module using data sets 64
    to 79. The parameters set in STEP 7 do not change in the CPU, which means the
    parameters set in STEP 7 are still valid after a restart.
    The parameters are only checked for plausibility by the module after the transferThe module ignores errors that occurred during the transfer of parameters with the WRREC
    instruction and continues operation with the previous parameter assignment. However, a
    corresponding error code is written to the STATUS output parameter.
    The description of the WRREC instruction and the error codes is available in the STEP 7
    online help64 to 79 and are assigned as follows:

    Contact Details
    Guang Zhou Lai Jie Electric Co.,Ltd

    Contact Person: Mr. Tommy

    Tel: 86-020-87268766

    Fax: 86-020-87269099

    Send your inquiry directly to us (0 / 3000)