



nd ET 200MP systems, e.g. diagnostics, communication, motion control, Web
server, OPC UA. |
|
You can download the documentation free of charge from the Changes and supplements to the manuals are documented in a Product Information. |
|
You can download the product information free of charge from the With "mySupport", your personal workspace, you make the best out of your Industry Online |
|
Support.
In "mySupport", you can save filters, favorites and tags, request CAx data and compile your
personal library in the Documentation area. In addition, your data is already filled out in
support requests and you can get an overview of your current requests at any time.
You must register once to use the full functionality of "mySupport"In the Documentation area in "mySupport" you can combine entire manuals or only parts of
these to your own manual.
You can export the manual as PDF file or in a format that can be edited later.
You can find "mySupport" - Documentation on the CAx data
In the CAx data area in "mySupport", you can access the current product data for your CAx
or CAe system.
You configure your own download package with a few clicks.
In doing so you can select:
● Product images, 2D dimension drawings, 3D models, internal circuit diagrams, EPLAN
macro files
● Manuals, characteristics, operating manuals, certificates
● Product master data
You can find "mySupport" - CAx data on the The application examples support you with various tools and examples for solving your
automation tasks. Solutions are shown in interplay with multiple components in the system -
separated from the focus on individual products.
You will find the application examples on the With the TIA Selection Tool, you can select, configure and order devices for Totally
Integrated Automation (TIA).
This tool is the successor of the SIMATIC Selection Tool and combines the known
configurators for automation technology into one tool.
With the TIA Selection Tool, you can generate a complete order list from your product
selection or product configuration.
You can find the TIA Selection Tool on the You can use the SIMATIC Automation Tool to run commissioning and maintenance activities
simultaneously on various SIMATIC S7 stations as a bulk operation independently of the
TIA Portal.
The SIMATIC Automation Tool provides a multitude of functions:
● Scanning of a PROFINET/Ethernet network and identification of all connected CPUs
● Address assignment (IP, subnet, gateway) and station name (PROFINET device) to a
CPU
● Transfer of the date and the programming device/PC time converted to UTC time to the
module
● Program download to CPU
● Operating mode switchover RUN/STOP
● Localization of the CPU by means of LED flashing
● Reading out CPU error information
● Reading the CPU diagnostic buffer
● Reset to factory settings
● Updating the firmware of the CPU and connected modules
You can find the SIMATIC Automation Tool on the With PRONETA (PROFINET network analysis), you analyze the PROFINET
network during commissioning. PRONETA features two core functions:
● The topology overview independently scans PROFINET and all connected components.
● The IO check is a fast test of the wiring and the module configuration of a system.
You can find PRONETA on the The module has the following technical properties:
● Digital inputs
– 16 digital inputs; electrically isolated in groups of 16
– Rated input voltage 24 VDC
– Suitable for switches and 2-/3-/4-wire proximity switches
● Digital outputs
– 16 digital outputs, electrically isolated in groups of 8
– Rated output voltage 24 VDC
– Rated output current 0.5 A per channel
– Suitable for solenoid valves, DC contactors, and indicator lights
The module supports the following functions:
The following components are supplied with the module and can also be ordered separately
as spare parts:
● Front connector (push-in terminals) including cable tie
● Labeling strips
● U connector
● Universal front door
You can find additional information on accessories in the /ET 200MP This section contains the block diagram of the module and outlines various wiring options.
You can find information on wiring the front connector, creating a cable shield, etc. in the
Wiring section of the /ET 200MP The figure below shows you how to connect the module and the assignment of the channels
to the addresses (input byte a and b, output byte c and d).The module can be configured in various ways in STEP 7. Depending on the configuration,
additional/different addresses are assigned in the process image input/output.
Configuration options of DI 16x24VDC/DQ 16x24VDC/0.5A BA
You can configure the module with STEP 7 (TIA Portal) or with a GSD file.
When you configure the module by means of the GSD file, the configurations are available
under different abbreviations/module names.
The following configurations are possible:
Table 4- 1 Configuration options
Configuration Short designation/