Home ProductsLeine linde

LENZE EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100

LENZE EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100

    • LENZE EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100
    • LENZE EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100
    • LENZE EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100
    • LENZE EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100
  • LENZE EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100

    Product Details:

    Place of Origin: GERMANY
    Brand Name: LENZE
    Certification: CE
    Model Number: EVS9325-ETV100

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Packaging Details: carton
    Delivery Time: in stock
    Payment Terms: T/T, Western Union, MoneyGram
    Supply Ability: 100pcs/week
    Contact Now
    Detailed Product Description
    LENZE: LENZE EVS9325-ETV100: EVS9325-ETV100
    GERMANY: GERMANY Temperature: 20-90
    Color: Black Dimension: 90mm
    Material: Iron

    LENZE EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100LENZE EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100LENZE EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100LENZE EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100 EVS9325-ETV100

    ERROR LED (red LED)
    ③ MAINT LED (yellow LED)
     
    LINK RX/TX LED for port X1 P1 (yellow/green LED)
    ⑤ LINK RX/TX LED for port X1 P2 (yellow/green LED
     
    Figure 4-1 LED display of the CPU 1511T-1 PN (without front panel)The CPU 1511T-1 PN has three LEDs to signal the current operating status and diagnostics  

    status. The following table shows the meaning of the various combinations of colors for the
    RUN/STOP, ERROR and MAINT LEDs.Each port has a LINK RX/TX LED. The table below shows the various "LED scenarios" of
    ports for the CPU 1511T-1 PN.
    Table 4- 2 Meaning of the LEDs
    LINK TX/RX LED Meaning
    LED off
    There is no Ethernet connection between the PROFINET interface of the PROFINET device
    and the communication partner.
    No data is currently being sent/received via the PROFINET interface.
    There is no LINK connection.
    LED flashes green
    The "LED flashing test" is being performed.
    LED lit green
    There is an Ethernet connection between the PROFINET interface of your PROFINET device
    and a communication partner.
    LED flickers yellow
    Data is currently being received from or sent to a communications partner on Ethernet via
    the PROFINET interface of the PROFINET deviceRetentive data area (incl. timers, counters,
    flags), max.
    128 kbyte; In total; available retentive memory for
    bit memories, timers, counters, DBs, and technology
    data (axes): 88 KB
    Extended retentive data area (incl. timers,
    counters, flags), max.
    1 Mbyte; When using PS 60W 24/48/60V DC HF
    Flag
    • Number, max. 16 kbyte
    • Number of clock memories 8; 8 clock memory bits, grouped into one clock
    memory byte
    Data blocks
    • Retentivity adjustable Yes
    • Retentivity preset No
    Local data
    • per priority class, max. 64 kbyte; max. 16 KB per block
    Address area
    Number of IO modules 1 024; max. number of modules / submodules
    • Inputs 32 kbyte; All inputs are in the process image
    • Outputs 32 kbyte; All outputs are in the process image
    per integrated IO subsystem
    – Inputs (volume) 8 kbyte
    – Outputs (volume) 8 kbyte
    per CM/CP
    – Inputs (volume) 8 kbyte
    – Outputs (volume) 8 kbyte
    Subprocess images
    • Number of subprocess images, max. 32
    Hardware configuration
    Number of distributed IO systems 32; A distributed I/O system is characterized not
    only by the integration of distributed I/O via
    PROFINET or PROFIBUS communication
    modules, but also by the connection of I/O via
    AS-i master modules or links (e.g. IE/PB-Link

    Number of DP masters
    • Via CM 4; A maximum of 4 CMs/CPs (PROFIBUS,
    PROFINET, Ethernet) can be inserted in total
    Number of IO Controllers
    • integrated 1
    • Via CM 4; A maximum of 4 CMs/CPs (PROFIBUS,
    PROFINET, Ethernet) can be inserted in total
    Rack
    • Modules per rack, max. 32; CPU + 31 modules
    • Number of lines, max. 1
    PtP CM
    • Number of PtP CMs the number of connectable PtP CMs is only
    limited by the number of available slots
    Time of day
    Clock
    • Type Hardware clock
    • Backup time 6 wk; At 40 °C ambient temperature, typically
    • Deviation per day, max. 10 s; Typ.: 2 sNumber of ports 2
    • integrated switch Yes
    • RJ 45 (Ethernet) Yes; X1
    Functionality
    • IP protocol Yes; IPv4
    • PROFINET IO Controller Yes
    • PROFINET IO Device Yes
    • SIMATIC communication Yes
    • Open IE communication Yes
    • Web server Yes
    • Media redundancy Yes; MRP Automanager according to
    IEC 62439-2 Edition 2.0Yes; As MRP redundancy manager and/or MRP
    client; max. number of devices in the ring: 50
    – MRPD Yes; Requirement: IRT
    – PROFIenergy Yes
    – Prioritized startup Yes; Max. 32 PROFINET devices
    – Number of connectable IO Devices,
    max.
    128; In total, up to 256 distributed I/O devices can
    be connected via AS-i, PROFIBUS or PROFINET
    – Of which IO devices with IRT, max. 64
    – Number of connectable IO Devices for
    RT, max.
    128of which in line, max. 128
    – Number of IO Devices that can be simultaneously
    activated/deactivated, max.
    8; in total across all interfaces
    – Number of IO Devices per tool, max. 8
    – Updating times The minimum value of the update time also
    depends on communication share set for
    PROFINET IO, on the number of IO devices, and
    on the quantity of configured user data
    Update time for IRT
    – for send cycle of 250 µs 250 μs to 4 ms; Note: In the case of IRT with
    isochronous mode, the minimum update time of
    625 µs of the isochronous OB is decisive
    – for send cycle of 500 µs 500 μs to 8 ms; Note: In the case of IRT with
    isochronous mode, the minimum update time of
    625 µs of the isochronous OB is decisive
    – for send cycle of 1 ms 1 ms to 16 ms
    – for send cycle of 2 ms 2 ms to 32 ms

     

    Contact Details
    Guang Zhou Lai Jie Electric Co.,Ltd

    Contact Person: Mr. Tommy

    Tel: 86-020-87268766

    Fax: 86-020-87269099

    Send your inquiry directly to us (0 / 3000)