Place of Origin: | GERMANY |
Brand Name: | LENZE |
Certification: | CE |
Model Number: | EVS9326-EK |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
LENZE: | LENZE | EVS9326-EK: | EVS9326-EK |
---|---|---|---|
GERMANY: | GERMANY | Material: | Iron |
Color: | Black | Temperature: | 20-90 |
Wire: | Wire | Dimension: | 80mm |
f which status variables, max. 200; per job – of which control variables, max. 200; per job |
|
orcing • Forcing, variables Peripheral inputs/outputs |
|
Number of variables, max. 200 Diagnostic buffer |
present Yes
• Number of entries, max. 1 000
– of which powerfail-proof 500
Traces
• Number of configurable Traces 4; Up to 512 KB of data per trace are possibleRUN/STOP LED Yes
• ERROR LED Yes
• MAINT LED Yes
• Connection display LINK TX/RX Yes
Supported technology objects
Motion Control Yes; Note: The number of technology objects
affects the cycle time of the PLC program; selection
guide via the TIA Selection Tool or SIZER
• Number of available Motion Control resources
for technology objects (except cam
disks)
800
• Required Motion Control resources
– per speed-controlled axis 40
– per positioning axis 80
– per synchronous axis 160
– per external encoder 80
– per output cam 20
– per cam track 160
– per probe 40
• Number of available Extended Motion
Control resources for technology objects
40
• Required Extended Motion Control
resources
– for each cam 2
– for each set of kinematics 30
• Positioning axis
– Number of positioning axes at motion
control cycle of 4 ms (typical value)
5
– Number of positioning axes at motion
control cycle of 8 ms (typical valueYes; Universal PID controller with integrated
optimization
• PID_3Step Yes; PID controller with integrated optimization
for valves
• PID-Temp Yes; PID controller with integrated optimization
for temperatur• horizontal installation, min. 0 °C
• horizontal installation, max. 60 °C; Display: 50 °C, at an operating temperature
of typically 50 °C, the display is switched off
• vertical installation, min. 0 °C
• vertical installation, max. 40 °C; Display: 40 °C, at an operating temperature
of typically 40 °C, the display is switched offUser program protection/password protection
Yes
• Copy protection Yes
• Block protection Yes
Access protection
• Password for display Yes
• Protection level: Write protection Yes
• Protection level: Read/write protection Yes
• Protection level: Complete protection You can find information on the general technical specifications, such as standards and
approvals, electromagnetic compatibility, protection class, etc., in the , ET 200MP
System ManuaThis section contains the dimensional drawing of the module on the mounting rail, as well as
a dimensional drawing with the front panel open. Always observe the specified dimensions
for installation in cabinets, control rooms, etcThis manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific