Place of Origin: | GERMANY |
Brand Name: | LENZE |
Certification: | CE |
Model Number: | EVS9328-ER |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
LENZE: | LENZE | Material: | Iron |
---|---|---|---|
Color: | Black | Temperature: | 20-90 |
Wire: | Wire | Germany: | Germany |
Dimension: | 80mm | EVS9328-ER: | EVS9328-ER |
(10 s) in the parameters | |
The new period duration is applied at the next rising edge of the outputYou assign the minimum pulse duration and the minimum interpulse period as DWORD | |
numerical value between 0 and 10 000 000 μs (10 s) with the help of the channel parameter configuration "Minimum pulse durationThe parameter "Output substitute |
value" generates a substitute
value upon CPU STOP, which you
can define with the parameter
"Substitute value for pulse output
(DQA)".
Output substitute value Output substitute
value
The parameter "Continue operation"
still generates the PWM output
signal upon CPU STOP, which
was generated before the CPU
STOP.
Continue operation
Substitute value
for pulse output
(DQA)
If you have set the option "Output
substitute value" for "Reaction to
CPU STOP", the parameter "Substitute
value for pulse output
(DQA)" defines the substitute
value to be used for the pulse
output of the channel.
If you have set the option "Continue
operation" for "Reaction to CPU
STOP", the parameter "Substitute
value for pulse output (DQA)"
cannot be selected
0
(use substitute value 0)
0
1
(use substitute value 1)
Diagnostics
interrupt
No supply voltage
L+
The parameter "No supply voltage
L+" activates the diagnostic interrupt
of the channel in the case of
no supply voltage L+
Deactivated Deactivated
Activated
Parameter High-speed output
(0.1 A)
The "High-speed output (0.1 A)"
parameter is used to specify
whether you want to use the selected
pulse output as high-speed
output. Requirement for this is that
the selected pulse output supports
the operation as high-speed output.
Deactivated
The output supports frequencies
of up to 10 kHz (load dependent)
and currents of up to 0.5 A or
frequencies of up to 100 Hz and
currents of up to 0.5 A depending
on the performance capability of
the selected output.
Deactivated
Activated
The output supports frequencies
of up to 100 kHz and currents of
up to 0.1 A.Defines the format of the ratio
value (on-load factor) in the field
"OUTPUT_VALUE" of the control
duration of the channel.
S7 analog output
Interprets the ratio value in the
field OUTPUT_VALUE" of the
control interface 1/27648 of the
current period duration.
Supported value range from 0 to
27 648
Per 100
Per 100
Interprets the ratio value in the
field "OUTPUT_VALUE"of the
control interface percentage value
of the current period duration.
Supported value range 0 to 100
Per 1,000
Interprets the ratio value in the
field "OUTPUT_VALUE"of the
control interface is a one-tenth
percentage point of the current
period duration.
Supported value range from 0 to
1 000
Per 10,000
Interprets the ratio value in the
field "OUTPUT_VALUE" of the
control interface is a onehundredth
percentage point of the
current period duration.
Supported value range from 0 to
10 000
Minimum pulse
duration
Defines the minimum pulse duration
and the minimum interpulse