Place of Origin: | GERMANY |
Brand Name: | LENZE |
Certification: | CE |
Model Number: | EVS9329-ES |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
LENZE: | LENZE | EVS9329-ES: | EVS9329-ES |
---|---|---|---|
GERMANY: | GERMANY | Color: | Black |
Temperature: | 20-90 | Dimension: | 80mm |
Wire: | Wire |
Pulse encoder Yes • Pulse encoder with direction Yes |
|
Pulse encoder with one impulse signal per count direction |
|
Errors/accuracies Linearity error (relative to input range), (+/-) 0.1 % |
Temperature error (relative to input range), (+/-
)
0.005 %/K
Crosstalk between the inputs, max. -60 dB
Repeat accuracy in steady state at 25 °C (relative
to input range), (+/-)
0.05 %
Output ripple (relative to output range, bandwidth
0 to 50 kHz), (+/-)
0.02 %
Linearity error (relative to output range), (+/-) 0.15 %
Temperature error (relative to output range),
(+/-)
0.005 %/KCrosstalk between the outputs, max. -80 dB
Repeat accuracy in steady state at 25 °C (relative
to output range), (+/-)
0.05 %
Operational error limit in overall temperature
range
• Voltage, relative to input range, (+/-) 0.3 %
• Current, relative to input range, (+/-) 0.3 %
• Resistance, relative to input range, (+/-) 0.3 %
• Resistance thermometer, relative to input
range, (+/-)
Pt100 Standard: ±2 K, Pt100 Climate: ±1 K,
Ni100 Standard: ±1.2 K, Ni100 Climate: ±1 K
• Voltage, relative to output range, (+/-) 0.3 %
• Current, relative to output range, (+/-) 0.3 %
Basic error limit (operational limit at 25 °C)
• Voltage, relative to input range, (+/-) 0.2 %
• Current, relative to input range, (+/-) 0.2 %
• Resistance, relative to input range, (+/-) 0.2 %
• Resistance thermometer, relative to input
range, (+/-)
Pt100 Standard: ±1 K, Pt100 Climate: ±0.5 K,
Ni100 Standard: ±0.6 K, Ni100 Climate: ±0.5 K
• Voltage, relative to output range, (+/-) 0.2 %
• Current, relative to output range, (+/-) 0.2 %
Interference voltage suppression for f = n x (f1 +/-
1 %), f1 = interference frequency
• Series mode interference (peak value of
interference < rated value of input range),
min.
30 dB
• Common mode voltage, max. 10 V
• Common mode interference, min. 60 dB; at 400 Hz: 50 dB
Interfaces
Number of PROFINET interfaces 1
1. Interface
Interface types
• Number of ports 2
• integrated switch Yes
• RJ 45 (Ethernet) Yes; IP protocol Yes; IPv4
• PROFINET IO Controller Yes
• PROFINET IO Device Yes
• SIMATIC communication Yes
• Open IE communication Yes
• Web server Yes
• Media redundancy Yes; MRP Automanager according to IEC 62439-
2 Edition 2.0
PROFINET IO Controller
Services
– PG/OP communication Yes
– S7 routing Yes
– Isochronous mode Yes
– Open IE communication Yes
– IRT Yes
– MRP Yes; As MRP redundancy manager and/or MRP
client; max. number of devices in the ring: 50
– MRPD Yes; Requirement: IRT
– Prioritized startup Yes; Max. 32 PROFINET devices
– Number of connectable IO Devices,
max.
128; In total, up to 512 distributed I/O devices can
be connected via AS-i, PROFIBUS or PROFINET
– Of which IO devices with IRT, max. 64
– Number of connectable IO Devices for
RT, max.
128
– of which in line, max. 128
– Number of IO Devices that can be simultaneously
activated/deactivated, max.
8; in total across all interfaces
– Number of IO Devices per tool, max. 8
– Updating times The minimum value of the update time also depends
on communication share set for
PROFINET IO, on the number of IO devices, and
on the quantity of configured user data250 μs to 4 ms; Note: In the case of IRT with
isochronous mode, the minimum update time of
625 µs of the isochronous OB is decisive
– for send cycle of 500 µs 500 μs to 8 ms; Note: In the case of IRT with
isochronous mode, the minimum update time of
625 µs of the isochronous OB is decisive
– for send cycle of 1 ms 1 ms to 16 ms
– for send cycle of 2 ms 2 ms to 32 ms
– for send cycle of 4 ms 4 ms to 64 ms
– With IRT and parameterization of "odd"
send cycles
Update time = set "odd" send clock (any multiple
of 125 µs: 375 µs, 625 µs ... 3 875 µs)
Update time for RT
– for send cycle of 250 µs 250 µs to 128 ms
– for send cycle of 500 µs 500 µs to 256 ms
– for send cycle of 1 ms 1 ms to 512 ms
– for send cycle of 2 ms 2 ms to 512 ms
– for send cycle of 4 ms 4 ms to 512 msNumber of connections, max. 128; via integrated interfaces of the CPU and
connected CPs / CMs
• Number of connections reserved for
ES/HMI/web
10
• Number of connections via integrated interfaces
88
• Number of S7 routing paths 16
PROFINET IO Controller