    Product Details:

    Place of Origin: GERMANY
    Brand Name: LENZE
    Certification: CE
    Model Number: EVS9329-ESV004

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Packaging Details: carton
    Delivery Time: in stock
    Payment Terms: T/T, Western Union, MoneyGram
    Supply Ability: 100pcs/week
    Contact Now
    Detailed Product Description
    LENZE: LENZE EVS9329-ESV004: EVS9329-ESV004
    GERMANY: GERMANY Material: Iron
    Color: Black Temperature: 20-90
    Dimension: 90mm

    LENZE EVS9329-ESV004 EVS9329-ESV004 EVS9329-ESV004 EVS9329-ESV004LENZE EVS9329-ESV004 EVS9329-ESV004 EVS9329-ESV004 EVS9329-ESV004LENZE EVS9329-ESV004 EVS9329-ESV004 EVS9329-ESV004 EVS9329-ESV004LENZE EVS9329-ESV004 EVS9329-ESV004 EVS9329-ESV004 EVS9329-ESV004

    Services
    – PG/OP communication Yes
    – S7 routing Yes
     
    Isochronous mode Yes
    – Open IE communication Yes
    – IRT Yes
     
    MRP Yes; As MRP redundancy manager and/or MRP
    client; max. number of devices in the ring: 50
     

    MRPD Yes; Requirement: IRT
    – PROFIenergy Yes
    – Prioritized startup Yes; Max. 32 PROFINET devices
    – Number of connectable IO Devices,
    max.
    128; In total, up to 512 distributed I/O devices can
    be connected via AS-i, PROFIBUS or PROFINETThe minimum value of the update time also depends
    on communication share set for
    PROFINET IO, on the number of IO devices, and
    on the quantity of configured user data
    SIMATIC communication
    • S7 communication, as server Yes
    • S7 communication, as client Yes
    • User data per job, max. See online help (S7 communication, user data
    size)Yes
    • OPC UA Server Yes; Data access (read, write, subscribe), method
    call, custom address space
    – Application authentication Yes
    – Security policies Available security policies: None,
    Basic128Rsa15, Basic256Rsa15,
    Basic256Sha256
    – User authentication "anonymous" or by user name & password
    Further protocols
    • MODBUS Yes; MODBUS TCP
    Media redundancy
    • Switchover time on line break, typ. 200 ms; For MRP, bumpless for MRPD
    • Number of stations in the ring, max. 50
    Isochronous mode
    Isochronous operation (application synchronized
    up to terminal)
    Yes; With minimum OB 6x cycle of 625 µs
    Equidistance YesNumber of login stations for message functions,
    max.
    32
    Program alarms Yes
    Number of configurable program alarms 5 000
    Number of simultaneously active program
    alarms
    • Number of program alarms 300
    • Number of alarms for system diagnostics 100
    • Number of alarms for motion technology
    objects
    80
    Test commissioning functions
    Joint commission (Team Engineering) Yes; Parallel online access possible for up to 5
    engineering systems
    Status block Yes; Up to 8 simultaneously (in total across all
    ES clients)
    Single step No
    Number of breakpoints 8
    Status/control
    • Status/control variable Yes
    • Variables Inputs/outputs, memory bits, DBs, distributed
    I/Os, timers, counters
    • Number of variables, max.
    – of which status variables, max. 200; per job
    – of which control variables, max. 200; per job
    Forcing
    • Forcing, variables Peripheral inputs/outputs
    • Number of variables, max. 200
    Diagnostic buffer
    • present Yes
    • Number of entries, max. 1 000

    of which powerfail-proof 500
    Traces
    • Number of configurable Traces 4; Up to 512 KB of data per trace are possible
    Interrupts/diagnostics/status information
    Alarms
    • Diagnostic alarm Yes
    • Hardware interrupt YeYes; Note: The number of axes affects the cycle
    time of the PLC program; selection guide via the
    TIA Selection Tool or SIZER
    • Number of available Motion Control resources
    for technology objects (except cam
    disks)
    800
    • Required Motion Control resources
    – per speed-controlled axis 40
    – per positioning axis 80
    – per synchronous axis 160
    – per external encoder 80
    – per output cam 20
    – per cam track 160
    – per probe 40
    • Positioning axis
    – Number of positioning axes at motion
    control cycle of 4 ms (typical value)
    5
    – Number of positioning axes at motion
    control cycle of 8 ms (typical value)
    10
    Controller
    • PID_Compact Yes; Universal PID controller with integrated
    optimization• Continuous counting Yes
    • Counter response parameterizable Yes
    • Hardware gate via digital input Yes
    • Software gate Yes
    • Event-controlled stop Yes
    • Synchronization via digital input Yes
    • Counting range, parameterizable Yes
    Comparator
    – Number of comparators 2; per count channel; see manual for details
    – Direction dependency Yes
    – Can be changed from user program Yes
    Position detection
    • Incremental acquisition Yes
    • Suitable for Motion Control Yes
    Measuring functions
    • Measuring time, parameterizable

     