Home ProductsLeine linde

LENZE EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET

LENZE EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET

    • LENZE EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET
    • LENZE EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET
    • LENZE EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET
    • LENZE EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET
  • LENZE EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET

    Product Details:

    Place of Origin: GERMANY
    Brand Name: LENZE
    Certification: CE
    Model Number: EVS9330-ET

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Packaging Details: carton
    Delivery Time: in stock
    Payment Terms: T/T, Western Union, MoneyGram
    Supply Ability: 100pcs/week
    Contact Now
    Detailed Product Description
    LENZE: LENZE EVS9330-ET: EVS9330-ET
    GERMANY: GERMANY Material: Iron
    Color: Black Temperature: 20-90
    Dimension: 90mm Wire: Wire

    LENZE EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ETLENZE EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ETLENZE EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ETLENZE EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET EVS9330-ET

    Retentivity adjustable Yes
    Retentivity preset No
     
    Local data
    Per priority class, max. 64 KB; max. 16 KB per block
     
    Address area
    Number of I/O modules 2048; max. number of modules/submodules
     

    I/O address area
    Inputs 32 KB; all inputs are in the process image
    Outputs 32 KB; all outputs are in the process image
    Of which per integrated IO subsystem
    • Inputs (volume) 8 KB
    • Outputs (volume) 8 KB
    Of which per CM/CP
    • Inputs (volume) 8 KB
    • Outputs (volume) 8 KB
    Process image partitions
    Number of process image partitions, max. 3232; a distributed IO system is understood to
    mean the integration of distributed I/O via
    PROFINET or PROFIBUS communication modules
    as well as the connection of I/O via AS-i
    master modules or links (e.g. IE/PB link)
    Number of DP masters
    Via CM 6; a maximum of 6 CMs (PROFINET +
    PROFIBUS) can be inserted in total
    Number of IO controllers
    Integrated 1
    Via CM 6; a maximum of 6 CMs (PROFINET +
    PROFIBUS) can be inserted in total
    Rack
    Modules per rack, max. 32; CPU + 31 modules
    Number of rows, max. 1
    PtP CM
    Number of PtP CMs The number of PtP CMs that can be connected is
    only limited by the available slots
    Type Hardware clock
    Backup duration 6 wk; at 40 °C ambient temperature, typ.
    Deviation per day, max. 10 s; typ.: 2 s
    Operating hours counter
    Quantity 16
    Time-of-day synchronization
    Supported Yes
    in AS, Master Yes
    in AS, Slave Yes
    On Ethernet via NTP Yes
    Interfaces
    Number of PROFINET interfaces 1
    1st interface
    Interface hardware
    Number of ports 2
    Integrated switch Yes
    RJ45 (Ethernet) Yes; X1
    Protocols
    PROFINET IO controller Yes
    PROFINET IO device Yes
    SIMATIC communication Yes
    Open IE communication Yes
    Web server Yes
    Media redundancy Yes
    Technical specifications
    CPU 1513-1 PN (6E513-1AL01-0AB0)
    Manual, 09/2016, A5E03506268-AD 37
    6E513-1AL01-0AB0
    PROFINET IO controller
    Services
    • PG/PG/OP communication Yes
    • routing Yes
    • Isochronous mode Yes
    • Open IE communication Yes
    • IRT Yes
    • MRP Yes; as MRP redundancy manager and/or MRP
    client; max. number of devices in the ring: 50
    • MRPD Yes; requirement: IRT
    • Prioritized startup Yes; max. 32 PROFINET devices
    • Number of connectable IO devices, max. 128
    • of these, IO devices with IRT, max. 64
    • Number of connectable IO devices for RT,
    max.
    128
    • of these, in a line topology, max. 128
    • Number of IO devices that can be activated/deactivated
    simultaneously, max.
    8; in total over all interfaces
    • Number of IO devices per tool, max. 8
    • Update times The minimum value of the update time also depends
    on the communication component set for
    PROFINET IO, on the number of IO devices, and
    on the quantity of configured user data.
    Update time with IRT
    • for send clock of 250 µs 250 µs to 4 ms; note: with IRT with isochronous
    mode, the minimum update time of 500 µs of the

    isochronous OB is crucial
    • With send clock of 500 µs 500 µs to 8 ms
    • With send clock of 1 ms 1 ms to 16 ms
    • with send clock of 2 ms 2 ms to 32 ms
    • with send clock of 4 ms 4 ms to 64 ms
    • with IRT and "odd" send clock parameter assignment
    Update time = set "odd" send clock (any multiple
    of 125 µs: 375 µs, 625 µs to 3 875 µs)or send clock of 250 µs 250 µs to 128 ms
    • With send clock of 500 µs 500 µs to 256 ms
    • With send clock of 1 ms 1 ms to 512 ms
    • with send clock of 2 ms 2 ms to 512 ms
    • with send clock of 4 ms 4 ms to 512 ms
    PROFINET IO device
    Services
    • PG/OP communication Yes
    • routing Yes
    • Isochronous mode No
    • Open IE communication Yes
    • IRT Yes
    • MRP Yes
    • MRPD Yes; requirement: IRT
    • PROFIenergy Yes
    • Shared device Yes
    • Number of IO controllers with shared device,
    max.
    4
    Interface hardware
    RJ 45 (Ethernet)
    100 Mbps Yes
    Autonegotiation Yes
    Autocrossing Yes
    Industrial Ethernet status LED Yes
    Protocols
    Number of connections
    Number of connections, max. 128; via integrated interfaces of the CPU and
    connected CPs/CMs
    Number of connections reserved for ES/HMI/Web 10
    Number of connections via integrated interfaces 88
    Number of routing connections 16Minimum value of update time also depends on
    the communication allocation setting for
    PROFINET IO, the number of IO devices and the
    amount of configured user data
    SIMATIC communication
    communication, as server Yes
    communication, as client Yes
    User data per job, max. See online help ( communication, user data
    size)Yes; standard and user-defined sites
    OPC UA
    OPC UA server Yes; Data Access (Read, Write, Subscribe),
    Runtime license required
    • Application authentication Yes
    • Security Policies Available Security Policies: None,
    Basic128Rsa15, Basic256Rsa15,
    Basic256Sha256
    • User authentication "Anonymous" or with user name and password
    Additional protocols
    MODBUS Yes; MODBUS TCP
    Media redundancy
    Switchover time in the case of cable break, typ. 200 ms; with MRP; bumpless with MRPD
    Number of devices in the ring, max. 50naling functions, max.
    32

    Contact Details
    Guang Zhou Lai Jie Electric Co.,Ltd

    Contact Person: Mr. Tommy

    Tel: 86-020-87268766

    Fax: 86-020-87269099

    Send your inquiry directly to us (0 / 3000)