Place of Origin: | GERMANY |
Brand Name: | LENZE |
Certification: | CE |
Model Number: | EVS9331-EK |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
LENZE: | LENZE | EVS9331-EK: | EVS9331-EK |
---|---|---|---|
Material: | Iron | Color: | Black |
Temperature: | 20-90 | Dimension: | 90mm |
Wire: | Wire |
Backup/restore of data from/to a backup file for CPUs and HMI devices ● Downloading service data from a CPU |
|
Reading the diagnostics buffer of a CPU ● Performing a CPU memory reset |
|
Resetting devices to factory settings ● Downloading a firmware update to a device |
You can find the SIMATIC Automation Tool on the With PRONETA (PROFINET network analysis), you analyze the PROFINET
network during commissioning. PRONETA features two core functions:
● The topology overview independently scans PROFINET network and all connected
components.
● The IO check is a fast test of the wiring and the module configuration of a system.
You can find PRONETA on the SINETPLAN, the Network Planner, supports you in planning automation systems
and networks based on PROFINET. The tool facilitates professional and predictive
dimensioning of your PROFINET installation as early as in the planning stage. In addition,
SINETPLAN supports you during network optimization and helps you to exploit network
resources optimally and to plan reserves. This helps to prevent problems in commissioning
or failures during productive operation even in advance of a planned operation. This
increases the availability of the production plant and helps improve operational safety.
The advantages at a glance
● Network optimization thanks to port-specific calculation of the network load
● Increased production availability thanks to online scan and verification of existing systems
● Transparency before commissioning through importing and simulation of existing STEP 7
projects
● Efficiency through securing existing investments in the long term and optimal exploitation
of resourcesThe module has the following technical properties:
● 32 DO; electrically isolated in groups of 8
● Rated output voltage 24 V DC
● Rated output current 0.5 A per channel
● Configurable substitute values (per channel)
● Configurable diagnostics (per channel)
● Suitable for solenoid valves, DC contactors, and indicator lights
● Switching cycle counter for connected actuators, e.g. solenoid valves
● Hardware compatible with digital output module:
– DQ 16x24VDC/0.5A ST (6ES7522-1BH00-0AB0)
– DQ 16x24VDC/0.5A HF (6ES7522-1BH01-0AB0)
– DQ 32x24VDC/0.5A ST (6ES7522-1BL00-0AB0)
The module supports the following functionsFirmware update V1.0.0 or higher X --- / X
Identification data I&M0 to I&M3 V1.0.0 or higher X X
Parameter assignment in RUN V1.0.0 or higher X X
Isochronous mode V1.0.0 or higher X ---
Module-internal Shared Output (MSO) V1.0.0 or higher X
(PROFINET IO only)
X
(PROFINET IO only)
Configurable submodules / submodules
for Shared Device
V1.0.0 or higher X
(PROFINET IO only)
X
(PROFINET IO only)
Switching cycle counter V1.1.0 or higher as of V15.0 with HSP0247
• PROFINET IO only
• Central operation with a
CPU is supported
X
(PROFINET IO only)
You can configure the module with STEP 7 (TIA Portal) and with a GSD file.The following table shows the compatibility of the modules and the dependencies between
hardware functional status (FS) and firmware version (FW) used:The following accessories are supplied with the module and can also be ordered separately
as spare parts:
● Labeling strips
● U connector
● Universal front cover
Other components
The following component must be ordered separately:
Front connectors, including potential jumpers and cable ties
You can find additional information on accessories in the system manual /ET 200MPThe function records the number of switching cycles of the output and thus the switching
cycles of a connected actuator, such as those of solenoid valves. When the specified
number of switching cycles is reached, the "Limit value warning" maintenance interrupt is
triggered, provided it is configured and enabled. When replacing the actuator, you can reset