Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5212 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
Tamagawa: | Tamagawa | TS5212: | TS5212 |
---|---|---|---|
COLOR: | BLACK | Material: | Iron |
Temperature: | 20-120 | Demention: | 50mm |
Wire: | Wire |
TS3103N156
TS5212
TS3617N2E4
TS3630N11E1
TS3664N2E4
TS3653N13E7
TS3653N12E6
TS3653N2E5
TS3624N2E3
TS3653N13E9
TS3653N2E6
TS3653N3E7
TS3653N3E8
TS3653N3E9
TS1980N43E12
TS1980N56E12
TS1981N134E9
TS1981N53E19
TS1981N56E19
TS1981N56E19
In the Message Blocks tab, configure the message blocks that are to be considered for the message list output.
In the Message Blocks tab, configure the message blocks that are to be considered for the message list output. | |
Assign the message blocks to the table columns of the message list in the Message List tab. Click the "Selection..." | |
button to open a dialog where you define the messages you want to output. |
The "WinCC Alarm Control/Table" report object is used to output the message lists in a tabular format. You can define dynamic parameters for output to message lists. In Runtime, the dynamic parameters are read from the system and written to the WinCC tags. The start values of the tags are overwritten
Value are supplied to WinCC tag through scripts, process-controlled actions or via other WinCC applications. An overview of the Runtime documentation parameters that can be dynamized is included in chapter Dynamizable Parameters for Runtime Documentation. Requirements ● The "WinCC Alarm Control/Table" object is pasted into the layout. ● The inserted object has been selected. ● The "Object properties" window is open ● Message configuration has been carried out in Alarm Logging ● You have configured the message list for the output via the static parameters.
In the "Link" tab of the "Object Properties" window, click the entry "Dynamized Parameterization". The dialog with the list of dynamizable properties opens.
In the Parameter list, click the property you want to dynamize. When you click with the mouse the "?" icon, you will get the following information: – Description of the properties – Format of the properties – Suitable tag type 3. Click the tag selection symbol on the upper right side. The tag selection dialog is displayed. 4. Select the desired tag, or create a new tag. Edit the properties of the tag in the tag selection dialog. If necessary, specify a start value for the tag. 5. Apply the settings by clicking OK and save the layout.
The report object "CCAxUserArchiveControl" serves for output of data from user archives outside of the WinCC UserArchiveControl. You specify the properties of the control in the Report Designer using the tabs of the WinCC UserArchiveControl.
The "CCAxUserArchiveControl" object is inserted in the layout. ● The inserted object is selected. ● The "Object properties" window is open. ● A user archive is created using the "User Archive" editor.
Double-click the "Properties" entry on the "Connect" tab in the "Object properties" window. The dialog with the properties of the control opens. 2. Specify the user archive that you want to use on the "General" tab. 3. Configure the properties of the control that you need to output or adapt the user archive on the tabs, for example, which columns you want to output or the representation of the table
How to configure the dynamic parameters of the WinCC UserArchiveControl