An automation system is installed and wired.he SIMATIC memory card is inserted in the CPU. Procedure |
RUN/STOP LED flashes alternately yellow/green – ERROR LED flashes redMAINT LED flashes yellow ● The CPU runs the system initialization and evaluates the SIMATIC memory card: – RUN/STOP LED flashes yellow at 2 Hz |
o commission a CPU, follow these steps: Switch on the system power supply and load current supply. Result: |
MAINT LED flashes yellow ● The CPU runs the system initialization and evaluates the SIMATIC memory card: – RUN/STOP LED flashes yellow at 2 Hz |
The CPU executes a flash test: – All LEDs flash at 2 Hz |
After the system initialization has been completed, the CPU goes to STOP mode: – The RUN/STOP LED lights up yellowThe commissioning of your automation system depends on the plant configuration. |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
TS3653N12E5
TS5320N632
TS2640N141E172
TS4507N1202E200
OSE5KN-6-12-108
TS3674N37
TS5013N69
TS3653N13E8
TS5420
TS2640N181E100
TS4507N1205E200
TS3166N43
TS3679N2E1
TS5208N131
TS3653N1E1
TS5641N150
TS2640N321E64
TS4507N1229E200
TS3212N32
RFH102422
TS3679N3E1
TS5208N111E78
TS3617N47E4
TS1508N211
TS2650N11E78
TS4507N2000E100
TS3214N12
RFH1024-22-1M-68
TS3682N1
TS3617N1E1
TS3624N1E1
TS1508N255
TS2651N111E78
TS4507N2070E100
TS3214N13
The following procedure describes the commissioning of the distributed I/O system on an IO
controller.
Commissioning procedure
To commission the ET 200MP as an IO device for PROFINET IO, we recommend the
following procedure:The operating mode transitions for the IO controller from RUN to STOP or from STOP to
RUN can take several milliseconds, until the mode transition for the inputs and outputs of all
I/O modules for the ET 200MP station is completed. This delay also applies to isochronous
modeThe commissioning of your automation system depends on the plant configuration.
The following procedure describes the commissioning of the ET 200MP distributed I/O
system on a DP master.
Commissioning procedure
To commission the ET 200MP as a DP slave for PROFIBUS DP, we recommend the
following procedure:During operating mode transitions of the DP master from RUN to STOP or from STOP to
RUN, it can take several milliseconds until the mode transition for the inputs and outputs of
all I/O modules of the ET 200MP is complete.Operating modes describe the states of the CPU. The following operating states are possible
via the mode selector:
● STARTUP
● RUN
● STOP
In these operating modes, the CPU can communicate, for example, via the PROFINET IO
interface (X1).
The status LEDs on the front side of the CPU indicate the current operating modeBefore the CPU starts to execute the cyclic user program, a startup program is executed.
By suitably programming startup OBs, you can specify initialization tags for your cyclic
program in the startup program. That is, you can set up one or several startup OBs in your
program, or none at all.All outputs are disabled or react according to the parameter settings for the respective
module: They provide a substitute value as set in the parameters or retain the last value
output and bring the controlled process to a safe operating mode.
● The process image is initialized.