Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5668N20 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | TS5668N20: | TS5668N20 |
---|---|---|---|
Japan: | Japan | Color: | Black |
Temperature: | 20-90 | Dimension: | 80mm |
Material: | Iron | Wire: | Wire |
TS5668N20
station option, enter 255. 5 Slot 1 of the station master Slot assignment 1 in the station option |
7 Slot 3 of the station master Slot assignment in the station option |
(always 1, because the CPU is always in slot 1) |
: : 4 + (max. slot number) |
6 Slot 2 of the station master Slot assignment in the station option |
Maximum slot of the station master |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
DIH48-6000C/T-P8-L6-5V
TS5246N430
TS1857N112
TS5213N551
TS5214N364
TS5312N512-2000C/TOSE.5KN-6-12-108
TS5146N11
BKO-NC6214
TS5214N500
48-2500PA-L6-5V
TS5205N4540IH60-8192C/T-P8-L6-5V
TS3699N172
TS3653N3E8
1510N122
TS3653N1E2
TS5667N120
TS3624N2E3
TS3738N1E7
TS2151N1E45
TS3699N232
TS3653N3E9
2000144
TS3653N2E4
TS5778N155
TS3624N2E4
TS4559N3E15
TS2151N11E45
TS3738N1E7
TS1980N43E12
482048P6L65V
TS3653N2E5
TS5778N157
TS3624N3E5
TS4886N9079E411
TS2640N321E64
TS3738N1E7
TS1980N56E12
60798024
TS3653N2E6
Slot assignment in the
station optionSystem power supply (optional) Upstream from interface module
1 Interface module Interface module (slot 1) is not an element of the
configuration control, but instead controls this
2 - 31 I/O modules/system power supplies, depending on
the station option
Downstream from the interface moduleBlock length 4 + number of slots Header
1 Block ID 196
2 Version 3
3 Version 0
4 Slot 0 of the station master Slot assignment in the
station option
Control element
Contains information on which module is
inserted in which slot.
The following rule determines which value
you must enter in the respective byte:
• If the module is included in the station
option, enter the slot number of the
module.
• If the module is not included in the
station option, enter 127.The feedback data record informs you about the accuracy of the module assignment and
gives you the option of detecting assignment errors in the control data record. The feedback
data record is mapped via a separate data record 197 V2.0.
Slot assignment
The feedback data record exists only when configuration control is configured and always
refers to the maximum quantity framework without interface module, i.e., 31 slots.
The following table shows the slot assignment of the modules:System power supply (optional) Upstream from interface module
2 - 31 I/O modules/system power supplies, depending on
the station option
Downstream from the interface module
Partial reading of the feedback data record is possibleThe data in the feedback data record is always mapped for all modules. In a Shared Device
configuration, it is therefore irrelevant which IO controller the respective modules are
assigned to.
As long as no control data record was sent, a one-to-one module assignment is assumed for
the compilation of data record 197 (station master → station option).s
In the case of an error when reading the feedback data record, the RDREC