Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5007N635 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | TS5007N635: | TS5007N635 |
---|---|---|---|
Japan: | Japan | COLOR: | Black |
Wire: | Wire | Temperature: | 20-80 |
Material: | Iron |
found in the section "Diagnostics of the modules". | |
The section below describes the structure and content of the various bytes in | |
data. In the bytoes 0...3, module errors are reported - errors that affect the entire module. |
TS3103N156
TS5007N635
TS3653N81E27
TS2025N471E69
TS3630N102E4
TS5017N60
TS5007N122
TS4502N1000E200
TS1983N146E5
TS3653N78E5
TS2014N181E32
TS3630N22E3
TS5108-N153-5V
TS5007N635
TS4502N1202E200
TS252N30E1
AU6270N103E63
TS3653N94E5
TS5208N141E78
TS3630N22E4
TS5146N10
TS5208N500
TS4502N2000E100
TS3503N11E43
Starting at byte 4, channel-specific errors are reported.
General rule: A fault is indicated by a logic "1" at the relevant bit.
Byte 0 to byte 3 (diagnostic data records 0 and 1)
Through entries in the diagnostic bytes byte 0 (bit 4...7) byte 2 and byte 3, module errors are
reported, which cannot be turned off through the setting of the module.
The section below describes the structure and content of the various bytes in diagnostics
data. General rule: A fault is indicated by a logic "1" at the relevant bit.
The next section describes the structure and contents of the various bytes in diagnostic data
of the position detection module SM 338; POS-INPUT. General rule: A fault is indicated by a
logic "1" at the relevant bit.
You will find a description of possible causes of problems and appropriate remedies in the
section titled Position detection module SM 338; POS-INPUT.
Data record 1 contains the channel-specific diagnostic data, starting at bytes 8 to 10. The
figure below shows the assignment of the diagnostic byte for a channel of
SM 338; POS-INPUT.
Data record 1 contains the channel-specific diagnostic data, starting at bytes 8 to 10. The
figure below shows the assignment of the diagnostic byte for a channel of
SM 338; POS-INPUT
This appendix contains the dimensional drawings of the most important components of an
S7-300. The specified dimensions are required to determine the dimensions of an S7-300
configuration. Make allowances for the dimensions of an S7-300 configuration when you
install the system in cabinets, control rooms, etc. This appendix does not include the
dimensional drawings of S7-300 or M7-300 CPUs, or of IM 153-1. These are included in the
relevant manuals.
Contents
This appendix contains the dimensional drawings of the S7-300 components listed below.
● Mounting rails
● Power supply modules
● Interface modules
● Signal modules
● AccessoriesThe figure below shows the dimensional drawing of the 483 mm standard rail.The figure below shows the dimensional drawing of the 530 mm standard rail.
The figure below shows the dimensional drawing of the 2000 mm standard rail.
The figure below shows the dimensional drawing of the 830 mm mounting rail
The figure below shows the dimensional drawing of the 2000 mm mounting rail.
The figure below shows the dimensional drawing of the mounting rail for the "Insertion and
Removal" function with active bus module, S7-300 mo
Explosion-proof partition
② S7-300 module
③ active bus module
④ Mounting rail for the "Insertion and Removal" function
S7307-1EA01-0AA0)
The drawing below shows the dimensions of power supply module PS 307; 5 A
The figures below show the dimensional drawings of a configuration consisting of a power
supply module PS 307; 10 A and a 313/314/315/315-2 DP CPU. Observe the dimensions
derived from the use of a power connector when wiring the PS 307; 10 A to the CPU.
Figure C-12 Dimensional drawing of power supply module PS 307; 10 A with CPU 313/314/315/315-
2 DP, front view
The side view drawing below shows the dimensions of power supply module PS 307; 10 A
with 313/314/315/315-2 DP CPU.
The figure below shows the dimensional drawing of interface module IM 360
The figure below shows the dimensional drawing of interface module IM 361.
The figure below shows the dimensional drawing of interface module IM 365.
The figure below shows the dimensional drawing of the signal module.
The signal module design may differ. The specified dimensions are always the same.
The figure below shows the dimension drawing for 64-channel I/O modules
The figure below shows the dimensional drawing of the shield connecting element used two
signal modules.
The figure below shows the dimension drawing of the 40-pin terminal block for 64-channel
signal modules.The table below lists the S7-300 parts you can order separately or