Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5208N569 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | Japan: | Japan |
---|---|---|---|
Temperature: | 30-80 | Color: | Black |
TS5208N569: | TS5208N569 | Material: | Iron |
Dimension: | 50mm |
emperature error of internal compensation | |
Defines the error to add to the actual | |
temperature error, when "internal comparison" mode is selected. The error is defined either |
TS3103N156
TS5208N569
TS5208N111E78
TS5208N141E78
TS5631N224
PULSE
GENERATOR
RP-182
750PPR
PULSE
GENERATOR
RP-182
1500PPR
PULSE
GENERATORRP-482E,750PPR
ROTALY
ENCODER
RP-112A-T1,750PPR
ROTALY
ENCODER
s a percentile value relative to the physical rated range of the analog module, or as an
absolute value in °C.
Glossary
S7-300 Module data
Manual, 06/2017, A5E00105505-AJ 637
Total current
Total current of all output channels of a digital output module.
ungrounded
no galvanic connection to ground potential
User program
Contains statements, tags and data for processing signals which can control a plant or
process. It is assigned to a programmable module (CPU, FM, for example) and can be
organized in smaller units (blocks).Parameter in STEP 7. A wirebreak check is used to monitor line continuity between the
encoder and input, or between the actuator and output. The module detects a wirebreak
based on a current flow at the appropriately programmed input/output.
Manual, 06/2017, A5E00105505-AJ 637ontains statements, tags and data for processing signals which can control a plant or
process. It is assigned to a programmable module (CPU, FM, for example) and can be
organized in smaller units (blocks).Parameter in STEP 7. A wirebreak check is used to monitor line continuity between the
encoder and input, or between the actuator and output. The module detects a wirebreak
based on a current flow at the appropriately programmed input/output.
if is not lost as a result of restart or power off.ScalingSTEP 7 parameter for the SM 338; POS-INPUT position detection module. Scaling rightaligns
the → Absolute encoder value in the address space; irrelevant places are discarded.
Segment
→ Bus segment
SFC
→ System Function
Signal module
Equipment used to amplify bus signals, and couple → bus segments across greater
distancesResolutionNumber of bits representing the value of analog modules in binary format. The resolution ismodule-specific. It is also determined by the → integration time of analog input modules. The
precision of the measured value resolution increases with the length of the integration time.
The maximum resolution is 16 bits + sign.Response to open thermocouple
ignal module
Signal modules (SMs) form the interface between the process and the automation system.
These are available as digital and analog input/output and IO modules.STEP 7 parameter for analog input modules. The measured values are smoothed by digital
filtering. Users can select module-specific filter properties, i.e. none, low, medium or high.
Programming device
A programming device (PG) is a special compact PC (Personal Computer) suitable for use in
industry. A PG is fully equipped for programming SIMATIC automation systems.
Reference junction
When operating thermocouples on analog input modules: point of known temperature
(for example, → compensating box.)
Reference potential
Potential from which the voltages of participating circuits are derived and measured.
Repeat accuracy
Denotes the maximum deviation between measured/output values, if the same input or
output signal is repeatedly set. Repeat accuracy refers to the rated range of the module, and
applies to its settled temperature state.
Glossary
S7-300 Module data
Manual, 06/2017, A5E00105505-AJ 635
Repeater
Equipment used to amplify bus signals, and couple → bus segments across greater
distances
Resolution