Home ProductsTAMAGAWA

TAMAGAWA TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160

TAMAGAWA TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160

    • TAMAGAWA TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160
    • TAMAGAWA TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160
    • TAMAGAWA TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160
    • TAMAGAWA TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160
  • TAMAGAWA TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160

    Product Details:

    Place of Origin: Japan
    Brand Name: Tamagawa
    Certification: CE
    Model Number: TS5246N160

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Packaging Details: carton
    Delivery Time: in stock
    Payment Terms: T/T, Western Union, MoneyGram
    Supply Ability: 100pcs/week
    Contact Now
    Detailed Product Description
    TAMAGAWA: TAMAGAWA TS5246N160: TS5246N160
    Japan: Japan Material: Iron
    Color: Black Wire: Wire
    Dimension: 70mm

     

     TAMAGAWA TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160TAMAGAWA TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160TAMAGAWA TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160TAMAGAWA TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160 TS5246N160

    For two-phase: CU is the Clock Up input, CD is the Clock Down input, HSC 5 and HSC 6 are available only with an SB. HSC 6 is available only with a 4-input SB.
    and [R] is an
    optional external reset input. (Reset is available only for "Counting" mode.)
    1 HSC 1 and HSC 2 can be configured for either the on-board inputs or for an SB.
    For AB-phase quadrature: A is the Clock A input, B is the Clock B input, and [R] is an
    optional external reset input. (Reset is available only for "Counting" mode.)

    Guang Zhou Lai Jie Electric Co.,LTD

    TS5246N160

    TS3624N3E6

    TS3630N1303E9

    TS3630N1309E5

    TS3630N1306

    TS3630N1E1

    TS3630N1E2

    TS3630N2E3

    TS3630N2E4

    TS3630N3E5

    TS3630N101E2

    TS3630N102E4

    TS3630N22E3

    TS3630N22E4

    TS3631N1E1

    TS3636N6

    TS3641N1E1

    TS3641N21E6

    TS3641N22E7

    TS3641N2E3

    TS3641N12E3

    TS3641N32

    An SB with only 2 digital inputs provides only the 4.0 and 4.1 inputs.For CPU 1214C: HSC 1, HSC 2, HSC 5 and HSC 6 can be configured for either the on-board
    inputs or for an SB.
    2 An SB with only 2 digital inputs provides only the 4.0 and 4.1 inputs.
    Accessing the current value for the HSC
    Note
    When you enable a pulse generator for use as a PTO, a corresponding HSC is assigned to
    this PTO. HSC1 is assigned for PTO1, and HSC2 is assigned for PTO2. The assigned HSC
    belongs completely to the PTO channel, and the ordinary output of the HSC is disabled. The
    HSC value is only used for the internal functionality. You cannot monitor the current value
    (for example, in ID1000) when pulses are occurring.
    The CPU stores the current value of each HSC in an input (I) address. The following table
    shows the default addresses assigned to the current value for each HSC. You can change
    the I address for the current value by modifying the properties of the CPU in the Device
    Configuration.
    Table 9- 10 Current value of the HSC The CPU allows you to configure up to 6 high-speed
    counters. You edit the "Properties" of the CPU to
    configure the parameters of each individual HSC.
    Use the CTRL_HSC instruction in your user program to
    control the operation of the HSC.
    Enable the specific HSC by selecting the "Enable" option
    for that HSC. When you enable the high speed counter and select input points for it, the input filter settings
    for these points are configured to 800 ns. Each input point has a single filter configuration
    that applies to all uses: process inputs, interrupts, pulse catch, and HSC inputs.
    WARNING
    If the filter time for a digital input channel is changed from a previous setting, a new "0"
    level input value may need to be presented for up to 20.0 ms accumulated duration before
    the filter becomes fully responsive to new inputs. During this time, short "0" pulse events of
    duration less than 20.0 ms may not be detected or counted.
    This changing of filter times can result in unexpected machine or process operation, which
    may cause death or serious injury to personnel, and/or damage to equipment.
    To ensure that a new filter time goes immediately into effect, a power cycle of the CPU
    must be applied.After enabling the HSC, configure the other parameters, such as counter function, initial
    values, reset options and interrupt events. STEP 7 provides the following PID instructions for the CPU:
    ● The PID_Compact instruction is used to control technical processes with continuous
    input- and output variables.

    Contact Details
    Guang Zhou Lai Jie Electric Co.,Ltd

    Contact Person: Mr. Tommy

    Tel: 86-020-87268766

    Fax: 86-020-87269099

    Send your inquiry directly to us (0 / 3000)