Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5420N60 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
Tamagawa: | Tamagawa | TS5420N60: | TS5420N60 |
---|---|---|---|
Japan: | Japan | Material: | Iron |
Color: | Black | Temperature: | 40-90 |
Dimension: | 60mm | Wire: | Wire |
Weekday of winter time: | character codes. A String header contains two lengths. The first byte is the maximum length |
Name of the zone: (GMT +01:00) Amsterdam, Berlin, Bern, Rome, Stockholm, Vienna | that is given in square brackets when you initialize a string, |
String data is stored as a 2-byte header followed by up to 254 character bytes of ASCII | or 254 by default. The second header byte is the current length that is the number of valid characters in the string. |
Guang Zhou Lai Jie Electric Co.,LTD
TS5420N60
TS5420N60
The current length must be smaller than or equal to the maximum length. The number of stored bytes occupied by the String format is 2 bytes greater than the maximum length.
tring data String input and output data must be initialized as valid strings in memory, before execution of any string instructions.
A valid string has a maximum length that must be greater than zero but less than 255. The current length must be less than or equal to the maximum length. Strings cannot be assigned to I or Q memory areas. For more information see: Format of the String data type (Page 97).
Copy the source IN string to the OUT location. S_MOVE execution does not affect the contents of the source string. If the actual length of the string at the input IN exceeds the maximum length of a string stored at output OUT, then the part of the IN string which can fit in the OUT string is copied.
You can convert number character strings to number values or number values to number character strings with these instructions: ● S_CONV converts (number string to a number value) or (number value to a number string) ● STRG_VAL converts a number string to a number value with format options ● VAL_STRG converts a number value to a number string with format options Converts a character string to the corresponding value, or a value to the corresponding character string. The S_CONV instruction has no output formatting options. This makes the S_CONV instruction simpler, but less flexible than the STRG_VAL and VAL_STRG instructions. For LAD / FBD: Click the "???" and select the data type from the drop-down list. 2 For SCL: Select S_CONV from the Extended Instructions, and answer the prompts for the data types for the conversion. STEP 7 then provides the appropriate conversion instruction. String Input character string OUT OUT String, Char, SInt, Int, DInt, USInt, UInt, UDInt, Real, LReal Output number value Conversion of the string parameter IN starts at the first character and continues until the end of the string, or until the first character is encountered that is not "0" through "9", "+", "-", or ".". The result value is provided at the location specified in parameter OUT. If the output number value does not fit in the range of the OUT data type, then parameter OUT is set to 0 and ENO is set to FALSE. Otherwise, parameter OUT contains a valid result and ENO is set to TRUE. Input String format rules: ● If a decimal point is used in the IN string, you must use the "." character. ● Comma characters "," used as a thousands separator to the left of the decimal point are allowed and ignored. ● Leading spaces are ignored.