Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5016N61 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | TS5016N61: | TS5016N61 |
---|---|---|---|
Japan: | Japan | Material: | Iron |
Color: | Black | Temperature: | 30-80 |
Dimension: | 70mm | Wire: | Wire |
When Done = 1 (or TRUE), ENO = 1 (or TRUE). | follow these steps: 1. In the "Device configuration" |
When Error = 1 (or TRUE), ENO = 0 (or FALSE). | select the CPU. 2. In the inspector window, |
See also OK and Not OK instructions (Page 197) To configure the password, |
select the "Properties" tab. 3. Select the "Protection |
Guang Zhou Lai Jie Electric Co.,LTD
TS5016N61
TS3664N12E4
TS3667N1E1
TS3667N1E2
TS3667N2E4
TS3667N1E3
TS3667N2E5
TS3667N2E6
TS3667N3E7
TS3667N3E8
TS3667N11E1
TS3667N11E2
TS3667N12E4
TS3667N11E3
TS3667N12E5
TS3667N12E6
TS3667N31E7
TS3667N13E8
TS3624N1E1
TS3624N1E2
TS3624N2E3
TS3624N2E4
TS3624N3E5
property to select the
protection level and to enter a
password.
Each level allows certain functions to be accessible without a password. The default
condition for the CPU is to have no restriction and no password-protection. To restrict access
to a CPU, you configure the properties of the CPU and enter the password.
Entering the password over a network does not compromise the password protection for the
CPU. Password protection does not apply to the execution of user program instructions
including communication functions. Entering the correct password provides access to all of
the functions.
PLC-to-PLC communications (using communication instructions in the code blocks) are not
restricted by the security level in the CPU. HMI functionality is also not restricted.
Table 6- 4 Security levels for the CPU
Security level Access restrictions
No protection Allows full access without password-protection.
Write protection Allows HMI access and all forms of PLC-to-PLC communications without password-protection.
Password is required for modifying (writing to) the CPU and for changing the CPU mode
(RUN/STOP).
Read/write protection Allows HMI access and all forms of PLC-to-PLC communications without password-protection.
Password is required for reading the data in the CPU, for modifying (writing to) the CPU, and for
changing the CPU mode (RUN/STOP).
6.6.2 Know-how protection
Know-how protection allows you to prevent one or more code blocks (OB, FB, FC, or DB) in
your program from unauthorized access. You create a password to limit access to the code
block. The password-protection prevents unauthorized reading or modification of the code
block. Without the password, you can read only the following information about the code
block:
● Block title, block comment, and block properties
● Transfer parameters (IN, OUT, IN_OUT, Return)
● Call structure of the program
● Global tags in the cross references (without information on the point of use), but local
tags are hidden When you configure a block for "know-how" protection, the code within the block cannot be
accessed except after entering the password.
Use the "Properties" task card of the code block to configure the know-how protection for
that block. After opening the code block, select "Protection" from Properties. Use the "Properties" task card of the code block to bind the block to a specific CPU or
memory card.
1. After opening the code block, select "Protection". From the drop-down list under "Copy protection" task, select the option to bind the code
block either to a memory card or to a specific CPU. Select the type of copy protection and enter the serial number for the memory card or
CPU. The serial number is case-sensitive. You can download the elements of your project from the programming device to the CPU.
When you download a project, the CPU stores the user program (OBs, FCs, FBs and DBs)
in permanent memory. You can download your project from the programming device to your CPU from any of the
following locations: