Home ProductsTAMAGAWA

TAMAGAWA TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364

TAMAGAWA TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364

    • TAMAGAWA TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364
    • TAMAGAWA TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364
    • TAMAGAWA TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364
    • TAMAGAWA TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364
  • TAMAGAWA TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364

    Product Details:

    Place of Origin: Japan
    Brand Name: Tamagawa
    Certification: CE
    Model Number: TS5214N364

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Packaging Details: carton
    Delivery Time: in stock
    Payment Terms: T/T, Western Union
    Supply Ability: 100pcs/week
    Contact Now
    Detailed Product Description
    TAMAGAWA: TAMAGAWA TS5214N364: TS5214N364
    Japan: Japan Material: Iron
    Color: Black Temperature: 20-80
    Wire: Wire Dimension: 50mm

     

     TAMAGAWA TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364TAMAGAWA TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364TAMAGAWA TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364 TS5214N364

    his section can only provide information on the protection of a programmable
    logic controller against overvoltages
     
    However, a complete protection against overvoltage is guaranteed only if the
    whole surrounding building is designed to provide protection against overvoltages.
     
    This refers especially to constructional measures for the building already in the
    planning phase.
     

    TS3103N156

    TS5214N364

    TS5303N510

    TS5622N131

    TS1616N200

    TS1501N13

    TS5641N154

    TS5205N454

    TS5668N20

    TS5667N120

    TS5667N420

    TS5308N616

    TS3462N1E76

    TS5214N561

    TS5214N510

    TS2014N182E32

    TS3653N2E5

    TS5320N510

    TS5016N60

    TS5016N60

    TS2651N111E78

    TS2014N181E32

    TS5208N130

    TS5214N566

    TS5205N450

    TS5205N454

    TS2651N11E78

    TS2651N141E78

    TS2651N1E78

    TS2651N131E78

    TS3103N40

    TS3653N2E5

    TS3653N3E8

    TS3684N1E3

    TS3684N2E6

    TS3684N3E8

    TS3667N3E8

    If you wish to obtain detailed information on overvoltage protection, we therefore
    recommend you to address your contact or a company specialized in
    lightning protection.The principle of the lightning protection zone concept states that the volume to be
    protected, for example, a manufacturing hall, is subdivided into lightning protection
    zones in accordance with EMC guidelines (see Figure A-6).
    The individual lightning protection zones are constituted by the following measures:
    The external lightning protection of the building (field side) Lightning protection
    zone 0
    The shielding of buildings Lightning protection
    zone 1
    The shielding of rooms Lightning protection
    zone 2
    The shielding of devices Lightning protection
    zone 3
    Effects of a Lightning Strike
    Direct lightning strikes occur in lightning protection zone 0. The lightning strike
    creates high-energy electromagnetic fields which can be reduced or removed from
    one lightning protection zone to the next by suitable lightning protection
    elements/measures.
    Surges
    In lightning protection zones 1 and higher, surges can result from switching
    operations and interference.The following diagram illustrates a lightning protection zone concept for a detached
    building.At the transition points between the lightning protection zones, you must take
    measures to prevent surges being conducted further.
    The lightning protection zone concept also states that all lines at the transitions
    between the lightning protection zones that can carry lightning stroke current must
    be included in the lightning protection equipotential bonding.
    Lines that can carry lightning stroke current include:
    • Metal pipelines (for example, water, gas and heat)
    • Power cables (for example, line voltage, 24 V supply)
    • Data cables (for example, bus cable)The following measures are suitable for lightning protection equipotential bonding
    at the transition between lightning protection zone 0 <-> 1:
    • Use grounded, spiralled, current-conducting metal strips or metal braiding, for
    example, NYCY or A2Y(K)Y, as a cable shield at the start and end
    • Lay the cables in one of the following ways:
    -- in continuous metal pipes that are grounded at the start and end

     

    Contact Details
    Guang Zhou Lai Jie Electric Co.,Ltd

    Contact Person: Mr. Tommy

    Tel: 86-020-87268766

    Fax: 86-020-87269099

    Send your inquiry directly to us (0 / 3000)