Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5778N155 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
Tamagawa: | Tamagawa | TS5778N155: | TS5778N155 |
---|---|---|---|
Japan: | Japan | Color: | Black |
Material: | Iron | Temperature: | 20-80 |
Wire: | Wire | Dimension: | 50mm |
TS3103N156
TS5778N155
TS4509N2405E200
TS4509N7000E100
TS4514N1021E200
TS4514N1407E200
TS4514N1828E200
TS4514N2002E200
TS4514N2405E200
TS4515N1202E200
TS4515N2405E200
TS4515N6000E200
TS4602N1000E200
TS4602N6321E100
TS4603N1000E100
TS4603N1000E200
TS4603N1532E200
TS4603N1700E200
TS4603N2002E200
TS4603N7002E200
TS1505N55
TS1508N211
TS1508N255
ET 200M
• ET 200S
• ET 200X
• ET 200eco
• All DP standard slavesYou may connect your to various subnets:
• via Simatic Net CP Ethernet to an Industrial Ethernet subnet
• via Simatic Net CP Profibus to a Profibus DP subnet
• via the integrated MPI interface to an MPI subnet
• via the integrated Profibus DP interface to a PROFIBUS DP subnet
See Chapter 5 for further details.Some of the accessories needed for fitting the modules in the rack are provided in
the packaging of the modules and racks. The front connectors of the signal
modules must always be ordered separately. There are also optional accessories
for some modules.
The accessories for modules and racks are listed and briefly explained in
Table 2-3. A list of spare parts for SIMATIC S7 can be found in the Reference
Manual, Appendix C as well as in the current CA 01 catalog.Rack (UR, CR,
ER)
Number wheel with
slot labels
-- For identifying the modules with
slot labels
Power Supply
Module (PS) -- 1 or 2 backup
batteries
For central backup of RAM areas
in the CPU
CPU -- Memory cards Load memories required for the
CPU
Signal Module
(SM)
2 labels
Plate with pinout
--
--
For labeling the inputs andoutputs on the front connectorTo identify the pinout of the frontconnectors-- Front connector withstrain relief for screw,crimp or spring-typeterminalFor wiring the SMs------Extraction tool (forcrimp terminals)Crimp contactsCrimping toolFor rewiring SMs with a frontconnector with crimpterminalsIn order to control a process, you must address the channels (inputs andoutputs)of the signal modules from the user program. You must establish a uniqueassignment between the(geographical) locIn which rack (0 to 21) is the signal module fittedation of a channel and an address in the
At which slot (1 to 18 or 1 to 9) in this rack is the signal module inserted? • Which channel (0 to 31) of this signal module is addressed? |
s:The logical address of a module and, therefore, of a channel is freely selectable |
In which rack (0 to 21) is the signal module fitted? | |
Section 3.2 describes the method of establishing the geographical address of a channel. Logical Addresses |
user program.Geographical Addresses
The geographical address of a particular channel is permanently assigned. It is
governed by the physical location of the input or output. In particular, this depends
on the following basic conditions:
is used in the program to address (read or write to) a particular input or output. The
physical location of the relevant module need not be known during programming.
You establish the assignment between logical and geographical address with
STEP 7.You assign the channel address in two stages: